Dayton Audio RS270P-4A
Paramètres Thiele-Small
| Taille nominale | 10" |
|---|---|
| Impédance | 4 Ω |
| Fs | 22.9 Hz |
| Qts | 0.272 |
| Qes | 0.34 |
| Qms | 1.35 |
| Vas | 110.5 L |
| Sd | 346.4 cm² |
| Xmax | 6 mm |
| Re | 3.9 Ω |
| Bl | 11 T·m |
| Mms | 73.5 g |
| Pe | 100 W |
| Sensibilité | 91 dB |
Indication d'alignement
| EBP | 67 · flexible |
|---|---|
| Sealed Vb (Qtc ≈ 0.71) | ≈ 19.2 L |
EBP 50-100 : fonctionne en clos ou en bass-reflex.
Rules of thumb from T/S parameters only. Verify against a real simulation before cutting wood.
Candidats de substitution
| HP | Fs (Hz) | Qts | Vas (L) | Xmax (mm) | Sens (dB) | Adéquation | Notes | Comparer |
|---|---|---|---|---|---|---|---|---|
| Visaton GF 250 - série | 24 +1.1 | 0.272 = | 134 +23.5 | 9.3 +3.3 | 91.1 +0.1 | close | 8 Ω vs 4 Ω: amp load changes | + |
| Visaton GF 250 v2017 - 2x4 Ohms série | 24 +1.1 | 0.272 = | 134 +23.5 | 9.3 +3.3 | 91.1 +0.1 | close | 8 Ω vs 4 Ω: amp load changes | + |
| Dayton Audio RS270-4 | 20.9 -2 | 0.277 +0.01 | 98.6 -11.9 | 6 = | 89.2 -1.8 | close | + | |
| Audiotechnology 10B773010KA | 24.4 +1.5 | 0.283 +0.01 | 128 +17.5 | 9.8 +3.8 | 91 = | close | 8 Ω vs 4 Ω: amp load changes | + |
| Axon 10K01 | 25 +2.1 | 0.286 +0.01 | 104.6 -5.9 | 7 +1 | 92.9 +1.9 | close | + | |
| Vifa M26WR09-04 | 27 +4.1 | 0.28 +0.01 | 113 +2.5 | 6.5 +0.5 | 93 +2 | close | 8 Ω vs 4 Ω: amp load changes | + |
| Audiotechnology FLEXUNITS 10 C 77 25 10 KAP | 25 +2.1 | 0.24 -0.03 | 110 -0.5 | 8.6 +2.6 | 90.2 -0.8 | close | 8 Ω vs 4 Ω: amp load changes | + |
| Dayton Audio RS270P-8A | 22.9 = | 0.319 +0.05 | 110.5 = | 6 = | 87.7 -3.3 | close | 8 Ω vs 4 Ω: amp load changes | + |
| Volt B250.8 | 24 +1.1 | 0.298 +0.03 | 126 +15.5 | 5.5 -0.5 | 90.3 -0.7 | close | 8 Ω vs 4 Ω: amp load changes · Xmax 5.5 mm < 6 mm: lower excursion-limited SPL | + |
| Audiotechnology 10C772510KAP | 25 +2.1 | 0.24 -0.03 | 110 -0.5 | 8.6 +2.6 | 92.1 +1.1 | close | 8 Ω vs 4 Ω: amp load changes | + |
Comparer les 3 plus proches avec le RS270P-4A →
Classé par similarité de paramètres uniquement (Qts, Fs, Vas, Xmax, sensibilité). Même taille nominale requise. Une indication, pas une simulation, modélisez l'échange avant de couper ou d'acheter.
Utilisé dans les caissons (0)
No enclosure in the catalog uses this driver yet.