← tous les HP

Dayton Audio 15LF ODEUM

15" · 8 Ω · 700 W · 96 dB · datasheet ↗

Paramètres Thiele-Small

Taille nominale15"
Impédance8 Ω
Fs25.5 Hz
Qts0.26
Qes0.27
Qms6.7
Vas331.3 L
Sd837.4 cm²
Xmax9.3 mm
Re6.4 Ω
Bl21 T·m
Mms115.6 g
Pe700 W
Sensibilité96 dB

Indication d'alignement

EBP94 · flexible
Sealed Vb (Qtc ≈ 0.71)≈ 51.8 L

EBP 50-100 : fonctionne en clos ou en bass-reflex.

Rules of thumb from T/S parameters only. Verify against a real simulation before cutting wood.

Candidats de substitution

HPFs (Hz)QtsVas (L)Xmax (mm)Sens (dB)AdéquationNotesComparer
Dayton Audio APOLLO 15LF25.5 =0.26 =331 -0.39.3 =96 =close+
Beyma 15k20027 +1.50.262 =345 +13.77.5 -1.897 +1close300 W vs 700 W: lower power handling · Xmax 7.5 mm < 9.3 mm: lower excursion-limited SPL+
Beyma SM-115/K27 +1.50.253 -0.01345 +13.78 -1.397.5 +1.5close500 W vs 700 W: lower power handling · Xmax 8 mm < 9.3 mm: lower excursion-limited SPL+
Scan-Speak 38WE/8582T0026 +0.50.243 -0.02423 +91.79.5 +0.297.5 +1.5close350 W vs 700 W: lower power handling+
Focal 38VX22.3 -3.20.279 +0.02347 +15.78.2 -1.196.9 +0.9close4 Ω vs 8 Ω: amp load changes · 225 W vs 700 W: lower power handling · Xmax 8.2 mm < 9.3 mm: lower excursion-limited SPL+
Magnat SUB 400 SUPREME21 -4.50.228 -0.03330 -1.39.5 +0.296.7 +0.7close4 Ω vs 8 Ω: amp load changes · 400 W vs 700 W: lower power handling+
Peerless SLS1524.1 -1.40.268 +0.01321.5 -9.86.4 -2.994.8 -1.2close200 W vs 700 W: lower power handling · Xmax 6.4 mm < 9.3 mm: lower excursion-limited SPL+
Magnat OMEGA 38021.3 -4.20.247 -0.01375 +43.712 +2.796.9 +0.9usable4 Ω vs 8 Ω: amp load changes · 500 W vs 700 W: lower power handling+
RCF L 15P200/A29 +3.50.291 +0.03280 -51.38.9 -0.496.6 +0.6usable300 W vs 700 W: lower power handling · Xmax 8.9 mm < 9.3 mm: lower excursion-limited SPL+
Rockford Fosgate PWR-41524 -1.50.283 +0.02334 +2.76.2 -3.197.4 +1.4usable4 Ω vs 8 Ω: amp load changes · Xmax 6.2 mm < 9.3 mm: lower excursion-limited SPL+

Comparer les 3 plus proches avec le 15LF ODEUM →

Classé par similarité de paramètres uniquement (Qts, Fs, Vas, Xmax, sensibilité). Même taille nominale requise. Une indication, pas une simulation, modélisez l'échange avant de couper ou d'acheter.

Utilisé dans les caissons (0)

No enclosure in the catalog uses this driver yet.