Davis 28MP10
Paramètres Thiele-Small
| Taille nominale | 10" |
|---|---|
| Impédance | 8 Ω |
| Fs | 40 Hz |
| Qts | 1.42 |
| Qes | 2.08 |
| Qms | 4.48 |
| Vas | 80.1 L |
| Sd | 330 cm² |
| Xmax | 3 mm |
| Re | 5.15 Ω |
| Bl | 4.3 T·m |
| Mms | 30.2 g |
| Pe | 60 W |
| Sensibilité | 87.8 dB |
Indication d'alignement
| EBP | 19 · sealed |
|---|---|
| Sealed Vb (Qtc ≈ 0.71) | Qts too high |
EBP < 50 : favorise un alignement clos.
Rules of thumb from T/S parameters only. Verify against a real simulation before cutting wood.
Candidats de substitution
| HP | Fs (Hz) | Qts | Vas (L) | Xmax (mm) | Sens (dB) | Adéquation | Notes | Comparer |
|---|---|---|---|---|---|---|---|---|
| Boss Audio CX10 | 36 -4 | 1.193 -0.23 | 75.9 -4.2 | 4 +1 | 85.9 -1.9 | usable | 4 Ω vs 8 Ω: amp load changes | + |
| Visaton WS25 E | 34 -6 | 1.435 +0.02 | 113 +32.9 | 3.6 +0.6 | 85.1 -2.7 | usable | + | |
| Visaton WS25 E 8 Ohms | 40 = | 0.995 -0.42 | 90 +9.9 | 4.6 +1.6 | 89 +1.2 | usable | + | |
| Europsonic HPC25/60 | 33.7 -6.3 | 1.217 -0.2 | 106.4 +26.3 | 2.9 -0.1 | 86.6 -1.2 | usable | 30 W vs 60 W: lower power handling · Xmax 2.9 mm < 3 mm: lower excursion-limited SPL | + |
| Goldwood GW-210/4 | 41.8 +1.8 | 1.067 -0.35 | 64.2 -15.9 | 3.5 +0.5 | 90.7 +2.9 | usable | 4 Ω vs 8 Ω: amp load changes | + |
| Goldwood GW-1038 | 33.7 -6.3 | 1.1 -0.32 | 90.299 +10.2 | 2.5 -0.5 | 85.5 -2.3 | usable | Xmax 2.5 mm < 3 mm: lower excursion-limited SPL | + |
| Jinwey YDY-250-8 | 41.8 +1.8 | 0.949 -0.47 | 69.3 -10.8 | 2 -1 | 88.4 +0.6 | usable | Xmax 2 mm < 3 mm: lower excursion-limited SPL | + |
| Kenford HW-1006 | 37 -3 | 0.787 -0.63 | 75 -5.1 | 4.7 +1.7 | 88.3 +0.5 | usable | + | |
| Hyper Phase BF10R | 45 +5 | 0.831 -0.59 | 78 -2.1 | 3.5 +0.5 | 90.8 +3 | usable | + | |
| Goldwood GW-1034 | 34.3 -5.7 | 0.881 -0.54 | 81.4 +1.3 | 2.5 -0.5 | 90.3 +2.5 | usable | 4 Ω vs 8 Ω: amp load changes · Xmax 2.5 mm < 3 mm: lower excursion-limited SPL | + |
Comparer les 3 plus proches avec le 28MP10 →
Classé par similarité de paramètres uniquement (Qts, Fs, Vas, Xmax, sensibilité). Même taille nominale requise. Une indication, pas une simulation, modélisez l'échange avant de couper ou d'acheter.
Utilisé dans les caissons (0)
No enclosure in the catalog uses this driver yet.