DAS Audio G-12 vp1
Paramètres Thiele-Small
| Taille nominale | 12" |
|---|---|
| Impédance | 8 Ω |
| Fs | 30.9 Hz |
| Qts | 0.389 |
| Qes | 0.45 |
| Qms | 2.89 |
| Vas | 166.2 L |
| Sd | 522.8 cm² |
| Xmax | 3 mm |
| Re | 6.57 Ω |
| Bl | 13.2 T·m |
| Mms | 61 g |
| Pe | 150 W |
| Sensibilité | 93.2 dB |
Indication d'alignement
| EBP | 69 · flexible |
|---|---|
| Sealed Vb (Qtc ≈ 0.71) | ≈ 72.1 L |
EBP 50-100 : fonctionne en clos ou en bass-reflex.
Rules of thumb from T/S parameters only. Verify against a real simulation before cutting wood.
Candidats de substitution
| HP | Fs (Hz) | Qts | Vas (L) | Xmax (mm) | Sens (dB) | Adéquation | Notes | Comparer |
|---|---|---|---|---|---|---|---|---|
| Philips AD12100W8 vp doum2 | 29.3 -1.6 | 0.399 +0.01 | 165 -1.2 | 6 +3 | 92.5 -0.7 | close | 100 W vs 150 W: lower power handling | + |
| Philips AD12100W8 vp doum1 | 29.9 -1 | 0.413 +0.02 | 166 -0.2 | 6 +3 | 92.5 -0.7 | close | 100 W vs 150 W: lower power handling | + |
| Focal 13V 7511 | 31.2 +0.3 | 0.353 -0.04 | 154.2 -12 | 6.8 +3.8 | 93.6 +0.4 | close | + | |
| EMS LB12EX_08V | 34 +3.1 | 0.414 +0.02 | 200 +33.8 | 3 = | 92.8 -0.4 | close | 16 Ω vs 8 Ω: amp load changes · 40 W vs 150 W: lower power handling | + |
| Ardan PRO W-31 | 36.4 +5.5 | 0.382 -0.01 | 170.6 +4.4 | 4 +1 | 95.3 +2.1 | close | + | |
| Selenium STREET BASS 12W2A | 30 -0.9 | 0.46 +0.07 | 164 -2.2 | 3.75 +0.75 | 91.5 -1.7 | close | 4 Ω vs 8 Ω: amp load changes | + |
| JBL 335151-001 | 28.2 -2.7 | 0.355 -0.03 | 177.3 +11.1 | 5 +2 | 93.8 +0.6 | close | 100 W vs 150 W: lower power handling | + |
| Supravox 285 GMF vp5 | 35 +4.1 | 0.372 -0.02 | 150 -16.2 | 4 +1 | 95.4 +2.2 | close | 70 W vs 150 W: lower power handling | + |
| Supravox 285 GMF vp6 | 35 +4.1 | 0.372 -0.02 | 150 -16.2 | 4 +1 | 95.4 +2.2 | close | 70 W vs 150 W: lower power handling | + |
| Philips AD12250W8 vp doum1 | 29.5 -1.4 | 0.404 +0.02 | 216 +49.8 | 6 +3 | 93.2 = | close | 100 W vs 150 W: lower power handling | + |
Comparer les 3 plus proches avec le G-12 vp1 →
Classé par similarité de paramètres uniquement (Qts, Fs, Vas, Xmax, sensibilité). Même taille nominale requise. Une indication, pas une simulation, modélisez l'échange avant de couper ou d'acheter.
Utilisé dans les caissons (0)
No enclosure in the catalog uses this driver yet.