Cube F10 SELECT
Paramètres Thiele-Small
| Taille nominale | 10" |
|---|---|
| Impédance | 8 Ω |
| Fs | 30 Hz |
| Qts | 0.567 |
| Qes | 0.6 |
| Qms | 10.4 |
| Vas | 121 L |
| Sd | 346 cm² |
| Xmax | 4.6 mm |
| Re | 6.5 Ω |
| Bl | 8.9 T·m |
| Mms | 39 g |
| Pe | 25 W |
| Sensibilité | 90.2 dB |
Indication d'alignement
| EBP | 50 · flexible |
|---|---|
| Sealed Vb (Qtc ≈ 0.71) | ≈ 217.9 L |
EBP 50-100 : fonctionne en clos ou en bass-reflex.
Rules of thumb from T/S parameters only. Verify against a real simulation before cutting wood.
Candidats de substitution
| HP | Fs (Hz) | Qts | Vas (L) | Xmax (mm) | Sens (dB) | Adéquation | Notes | Comparer |
|---|---|---|---|---|---|---|---|---|
| SEAS 25F-WBX | 32 +2 | 0.597 +0.03 | 114.5 -6.5 | 6 +1.4 | 89.9 -0.3 | close | + | |
| Monacor SP-254TC | 30 = | 0.505 -0.06 | 109 -12 | 5 +0.4 | 90 -0.2 | close | + | |
| Cube F10 NEO | 30 = | 0.505 -0.06 | 127 +6 | 5.1 +0.5 | 91.8 +1.6 | close | + | |
| Morel MW 1075 | 29 -1 | 0.622 +0.06 | 123 +2 | 4.3 -0.3 | 88.6 -1.6 | close | Xmax 4.3 mm < 4.6 mm: lower excursion-limited SPL | + |
| SEAS 25F-WBC vp1 Gils | 35.1 +5.1 | 0.58 +0.01 | 129.6 +8.6 | 6 +1.4 | 90.1 -0.1 | close | 16 Ω vs 8 Ω: amp load changes | + |
| Audax SON28A vp | 30 = | 0.505 -0.06 | 114.2 -6.8 | 4 -0.6 | 89.1 -1.1 | close | Xmax 4 mm < 4.6 mm: lower excursion-limited SPL | + |
| SEAS 25F-WBC vp2 Gils | 35.1 +5.1 | 0.58 +0.01 | 129.6 +8.6 | 4 -0.6 | 90.1 -0.1 | close | 16 Ω vs 8 Ω: amp load changes · Xmax 4 mm < 4.6 mm: lower excursion-limited SPL | + |
| Europsonic HP25/100 vp | 36.6 +6.6 | 0.552 -0.01 | 124.4 +3.4 | 5.5 +0.9 | 91.6 +1.4 | close | + | |
| Visaton GF 250 - 2x4 Ohms série | 26 -4 | 0.554 -0.01 | 110 -11 | 10 +5.4 | 91 +0.8 | close | 4 Ω vs 8 Ω: amp load changes | + |
| Dayton Audio DC250-8 | 28.9 -1.1 | 0.445 -0.12 | 111.4 -9.6 | 4.5 -0.1 | 90.1 -0.1 | close | Xmax 4.5 mm < 4.6 mm: lower excursion-limited SPL | + |
Comparer les 3 plus proches avec le F10 SELECT →
Classé par similarité de paramètres uniquement (Qts, Fs, Vas, Xmax, sensibilité). Même taille nominale requise. Une indication, pas une simulation, modélisez l'échange avant de couper ou d'acheter.
Utilisé dans les caissons (0)
No enclosure in the catalog uses this driver yet.