← tous les HP

CSS Audio SDX12 DVC

12" · 4 Ω · 800 W · 87.3 dB · datasheet ↗

Paramètres Thiele-Small

Taille nominale12"
Impédance4 Ω
Fs21.3 Hz
Qts0.375
Qes0.414
Qms3.962
Vas67.5 L
Sd491 cm²
Xmax13.4 mm
Re3.7 Ω
Bl18.3 T·m
Mms279.5 g
Pe800 W
Sensibilité87.3 dB

Indication d'alignement

EBP51 · flexible
Sealed Vb (Qtc ≈ 0.71)≈ 26.4 L

EBP 50-100 : fonctionne en clos ou en bass-reflex.

Rules of thumb from T/S parameters only. Verify against a real simulation before cutting wood.

Candidats de substitution

HPFs (Hz)QtsVas (L)Xmax (mm)Sens (dB)AdéquationNotesComparer
RE Audio XXX12-V2-421 -0.30.404 +0.0373.9 +6.413.5 +0.186.5 -0.8close8 Ω vs 4 Ω: amp load changes+
Dayton Audio RSS315HO-44 v201621.5 +0.20.369 -0.0161.3 -6.211.3 -2.184.6 -2.7close8 Ω vs 4 Ω: amp load changes · Xmax 11.3 mm < 13.4 mm: lower excursion-limited SPL+
Dayton Audio RSS315HO-4420.9 -0.40.382 +0.0160.1 -7.411.5 -1.989.9 +2.6close2 Ω vs 4 Ω: amp load changes · Xmax 11.5 mm < 13.4 mm: lower excursion-limited SPL+
Infinity REFERENCE 1260W23.5 +2.20.39 +0.0283 +15.513 -0.486 -1.3close300 W vs 800 W: lower power handling · Xmax 13 mm < 13.4 mm: lower excursion-limited SPL+
Oxygen AIR2 300 v201522.7 +1.40.388 +0.0178 +10.59.9 -3.589.1 +1.8usable300 W vs 800 W: lower power handling · Xmax 9.9 mm < 13.4 mm: lower excursion-limited SPL+
Eclipse 8712.820 -1.30.39 +0.0284.95 +17.4518.5 +5.184.1 -3.2usable8 Ω vs 4 Ω: amp load changes · 200 W vs 800 W: lower power handling+
Morel ULTIMO 12426 +4.70.421 +0.0573.8 +6.314.6 +1.289 +1.7usable+
Rockford Fosgate RFR221224 +2.70.376 =93 +25.513 -0.490.5 +3.2usableXmax 13 mm < 13.4 mm: lower excursion-limited SPL+
JL Audio 12W6V2-D425 +3.70.45 +0.0879.9 +12.412.7 -0.786.9 -0.4usable8 Ω vs 4 Ω: amp load changes · 600 W vs 800 W: lower power handling · Xmax 12.7 mm < 13.4 mm: lower excursion-limited SPL+
Alpine SWG-124428 +6.70.38 +0.0175 +7.510 -3.487.7 +0.4usable250 W vs 800 W: lower power handling · Xmax 10 mm < 13.4 mm: lower excursion-limited SPL+

Comparer les 3 plus proches avec le SDX12 DVC →

Classé par similarité de paramètres uniquement (Qts, Fs, Vas, Xmax, sensibilité). Même taille nominale requise. Une indication, pas une simulation, modélisez l'échange avant de couper ou d'acheter.

Utilisé dans les caissons (0)

No enclosure in the catalog uses this driver yet.