Clarion SRM2591
Paramètres Thiele-Small
| Taille nominale | 10" |
|---|---|
| Impédance | 4 Ω |
| Fs | 43 Hz |
| Qts | 0.398 |
| Qes | 0.44 |
| Qms | 4.18 |
| Vas | 31.1 L |
| Sd | 343.2 cm² |
| Xmax | 3.5 mm |
| Re | 3.5 Ω |
| Bl | 12.5 T·m |
| Mms | 72.7 g |
| Pe | 150 W |
| Sensibilité | 93.1 dB |
Indication d'alignement
| EBP | 98 · flexible |
|---|---|
| Sealed Vb (Qtc ≈ 0.71) | ≈ 14.4 L |
EBP 50-100 : fonctionne en clos ou en bass-reflex.
Rules of thumb from T/S parameters only. Verify against a real simulation before cutting wood.
Candidats de substitution
| HP | Fs (Hz) | Qts | Vas (L) | Xmax (mm) | Sens (dB) | Adéquation | Notes | Comparer |
|---|---|---|---|---|---|---|---|---|
| Goldwood GW-10PC/4 | 43.1 +0.1 | 0.404 +0.01 | 32.7 +1.6 | 4.8 +1.3 | 92.9 -0.2 | close | + | |
| PHL Audio 3002 | 45 +2 | 0.357 -0.04 | 35 +3.9 | 4 +0.5 | 92.9 -0.2 | close | 8 Ω vs 4 Ω: amp load changes | + |
| Focal 10V 6412 | 50 +7 | 0.423 +0.02 | 32.8 +1.7 | 3.3 -0.2 | 93.4 +0.3 | close | 8 Ω vs 4 Ω: amp load changes · 100 W vs 150 W: lower power handling · Xmax 3.3 mm < 3.5 mm: lower excursion-limited SPL | + |
| Turbosound TS-10W300/8A | 53 +10 | 0.415 +0.02 | 31.6 +0.5 | 3.4 -0.1 | 92.4 -0.7 | close | 8 Ω vs 4 Ω: amp load changes · Xmax 3.4 mm < 3.5 mm: lower excursion-limited SPL | + |
| PHL Audio 3002 v2010 | 48.6 +5.6 | 0.436 +0.04 | 29 -2.1 | 4 +0.5 | 92.3 -0.8 | close | 8 Ω vs 4 Ω: amp load changes | + |
| Oberton 10B200 | 48.06 +5.06 | 0.349 -0.05 | 31.94 +0.84 | 5.75 +2.25 | 93 -0.1 | close | 8 Ω vs 4 Ω: amp load changes | + |
| Focal 25 A1 | 40.6 -2.4 | 0.382 -0.02 | 24.3 -6.8 | 4.4 +0.9 | 91.9 -1.2 | close | + | |
| Zeuz 10500X | 48.4 +5.4 | 0.445 +0.05 | 34.6 +3.5 | 4.3 +0.8 | 94.5 +1.4 | usable | + | |
| Oberton 10B100 | 44 +1 | 0.447 +0.05 | 40.5 +9.4 | 4.4 +0.9 | 92.5 -0.6 | usable | 8 Ω vs 4 Ω: amp load changes · 100 W vs 150 W: lower power handling | + |
| Focal 27 H | 46.6 +3.6 | 0.499 +0.1 | 30.4 -0.7 | 5 +1.5 | 93.7 +0.6 | usable | + |
Comparer les 3 plus proches avec le SRM2591 →
Classé par similarité de paramètres uniquement (Qts, Fs, Vas, Xmax, sensibilité). Même taille nominale requise. Une indication, pas une simulation, modélisez l'échange avant de couper ou d'acheter.
Utilisé dans les caissons (0)
No enclosure in the catalog uses this driver yet.