Ciare HW320
Paramètres Thiele-Small
| Taille nominale | 12" |
|---|---|
| Impédance | 8 Ω |
| Fs | 27 Hz |
| Qts | 0.445 |
| Qes | 0.51 |
| Qms | 3.5 |
| Vas | 293 L |
| Sd | 510 cm² |
| Xmax | 4.1 mm |
| Re | 6.5 Ω |
| Bl | 9.7 T·m |
| Mms | 43.2 g |
| Pe | 120 W |
| Sensibilité | 93.4 dB |
Indication d'alignement
| EBP | 53 · flexible |
|---|---|
| Sealed Vb (Qtc ≈ 0.71) | ≈ 192.1 L |
EBP 50-100 : fonctionne en clos ou en bass-reflex.
Rules of thumb from T/S parameters only. Verify against a real simulation before cutting wood.
Candidats de substitution
| HP | Fs (Hz) | Qts | Vas (L) | Xmax (mm) | Sens (dB) | Adéquation | Notes | Comparer |
|---|---|---|---|---|---|---|---|---|
| Sphynx SP-W12-BK | 28 +1 | 0.417 -0.03 | 258 -35 | 4 -0.1 | 93.9 +0.5 | close | Xmax 4 mm < 4.1 mm: lower excursion-limited SPL | + |
| Sphynx SP-W12 | 28 +1 | 0.415 -0.03 | 258 -35 | 4 -0.1 | 93.9 +0.5 | close | Xmax 4 mm < 4.1 mm: lower excursion-limited SPL | + |
| Celestion T1600 vp 2 | 30.3 +3.3 | 0.44 -0.01 | 264.7 -28.3 | 4 -0.1 | 94.3 +0.9 | close | 80 W vs 120 W: lower power handling · Xmax 4 mm < 4.1 mm: lower excursion-limited SPL | + |
| Audax PR300M0 vp AP | 26.9 -0.1 | 0.448 = | 231 -62 | 4.4 +0.3 | 92.2 -1.2 | close | + | |
| JBL 125A | 25 -2 | 0.433 -0.01 | 235 -58 | 4.8 +0.7 | 92.9 -0.5 | close | 50 W vs 120 W: lower power handling | + |
| JBL 127A | 25 -2 | 0.433 -0.01 | 235 -58 | 4.8 +0.7 | 92.9 -0.5 | close | 50 W vs 120 W: lower power handling | + |
| Davis 31TK12-M vp | 27.8 +0.8 | 0.416 -0.03 | 376 +83 | 5 +0.9 | 94.5 +1.1 | close | + | |
| Celestion T1600 vp 1 | 23.6 -3.4 | 0.463 +0.02 | 350 +57 | 4 -0.1 | 92.2 -1.2 | close | 80 W vs 120 W: lower power handling · Xmax 4 mm < 4.1 mm: lower excursion-limited SPL | + |
| Max Speaker PV-1230 4 Ohms | 20 -7 | 0.452 +0.01 | 317 +24 | 4 -0.1 | 93.4 = | close | 4 Ω vs 8 Ω: amp load changes · Xmax 4 mm < 4.1 mm: lower excursion-limited SPL | + |
| AE Speakers LO12-D8 | 27.5 +0.5 | 0.431 -0.01 | 273 -20 | 9 +4.9 | 97.1 +3.7 | close | 4 Ω vs 8 Ω: amp load changes | + |
Comparer les 3 plus proches avec le HW320 →
Classé par similarité de paramètres uniquement (Qts, Fs, Vas, Xmax, sensibilité). Même taille nominale requise. Une indication, pas une simulation, modélisez l'échange avant de couper ou d'acheter.
Utilisé dans les caissons (0)
No enclosure in the catalog uses this driver yet.