← tous les HP

Ciare HSB322-22 vp

12" · 4 Ω · 350 W · 96.4 dB · datasheet ↗

Paramètres Thiele-Small

Taille nominale12"
Impédance4 Ω
Fs42.5 Hz
Qts0.484
Qes0.53
Qms5.59
Vas77 L
Sd510.7 cm²
Xmax7.3 mm
Re3.26 Ω
Bl10.5 T·m
Mms66.6 g
Pe350 W
Sensibilité96.4 dB

Indication d'alignement

EBP80 · flexible
Sealed Vb (Qtc ≈ 0.71)≈ 67.9 L

EBP 50-100 : fonctionne en clos ou en bass-reflex.

Rules of thumb from T/S parameters only. Verify against a real simulation before cutting wood.

Candidats de substitution

HPFs (Hz)QtsVas (L)Xmax (mm)Sens (dB)AdéquationNotesComparer
Faital PRO 12PR33052 +9.50.49 +0.0176.3 -0.77.27 -0.0397 +0.6close16 Ω vs 4 Ω: amp load changes · Xmax 7.27 mm < 7.3 mm: lower excursion-limited SPL+
Beyma 12CMV249 +6.50.47 -0.0176 -17 -0.394 -2.4close8 Ω vs 4 Ω: amp load changes · Xmax 7 mm < 7.3 mm: lower excursion-limited SPL+
Faital PRO 12PR32045 +2.50.52 +0.0496.7 +19.77.27 -0.0396 -0.4close16 Ω vs 4 Ω: amp load changes · Xmax 7.27 mm < 7.3 mm: lower excursion-limited SPL+
Beyma SM112/N v201243 +0.50.434 -0.0594 +177.3 =95.3 -1.1close8 Ω vs 4 Ω: amp load changes+
Faital PRO 12FH53045 +2.50.39 -0.0975.6 -1.47.5 +0.297 +0.6close16 Ω vs 4 Ω: amp load changes+
Radian CRS123048 +5.50.464 -0.0276 -15.5 -1.895.8 -0.6close8 Ω vs 4 Ω: amp load changes · Xmax 5.5 mm < 7.3 mm: lower excursion-limited SPL+
DAS Audio 12P46.2 +3.70.459 -0.0273.6 -3.46 -1.394.6 -1.8close8 Ω vs 4 Ω: amp load changes · Xmax 6 mm < 7.3 mm: lower excursion-limited SPL+
Beyma SM212 vp N&ordm;145.8 +3.30.456 -0.0387.1 +10.16.5 -0.894.8 -1.6close8 Ω vs 4 Ω: amp load changes · Xmax 6.5 mm < 7.3 mm: lower excursion-limited SPL+
Faital PRO 12PR320 16 Ohms45 +2.50.522 +0.0480.8 +3.87.3 =91.7 -4.7close16 Ω vs 4 Ω: amp load changes+
Audax HT300G036.8 -5.70.531 +0.0577.7 +0.76.6 -0.794.4 -2close225 W vs 350 W: lower power handling · Xmax 6.6 mm < 7.3 mm: lower excursion-limited SPL+

Comparer les 3 plus proches avec le HSB322-22 vp →

Classé par similarité de paramètres uniquement (Qts, Fs, Vas, Xmax, sensibilité). Même taille nominale requise. Une indication, pas une simulation, modélisez l'échange avant de couper ou d'acheter.

Utilisé dans les caissons (0)

No enclosure in the catalog uses this driver yet.