Celestion TF 1215
Paramètres Thiele-Small
| Taille nominale | 12" |
|---|---|
| Impédance | 8 Ω |
| Fs | 62 Hz |
| Qts | 0.857 |
| Qes | 1 |
| Qms | 6 |
| Vas | 69 L |
| Sd | 517 cm² |
| Xmax | 2.5 mm |
| Re | 5 Ω |
| Bl | 8.3 T·m |
| Mms | 35.8 g |
| Pe | 250 W |
| Sensibilité | 96.2 dB |
Indication d'alignement
| EBP | 62 · flexible |
|---|---|
| Sealed Vb (Qtc ≈ 0.71) | Qts too high |
EBP 50-100 : fonctionne en clos ou en bass-reflex.
Rules of thumb from T/S parameters only. Verify against a real simulation before cutting wood.
Candidats de substitution
| HP | Fs (Hz) | Qts | Vas (L) | Xmax (mm) | Sens (dB) | Adéquation | Notes | Comparer |
|---|---|---|---|---|---|---|---|---|
| SICA 12 D 1.5 CS 8 Ohms | 62 = | 0.748 -0.11 | 63.5 -5.5 | 2.7 +0.2 | 96.8 +0.6 | close | 100 W vs 250 W: lower power handling | + |
| Sica 12 D 1.5 CS | 62 = | 0.75 -0.11 | 63.5 -5.5 | 2.7 +0.2 | 96.9 +0.7 | close | 130 W vs 250 W: lower power handling | + |
| Mercuriale PTR 306 M0 | 58 -4 | 0.808 -0.05 | 70.1 +1.1 | 3.9 +1.4 | 94.6 -1.6 | close | 150 W vs 250 W: lower power handling | + |
| Monacor SP-300GI | 65 +3 | 0.969 +0.11 | 75 +6 | 3.2 +0.7 | 94.9 -1.3 | close | 150 W vs 250 W: lower power handling | + |
| Peavey S-12825 | 59.4 -2.6 | 0.611 -0.25 | 66.6 -2.4 | 2.5 = | 96.8 +0.6 | usable | + | |
| Fane 12-100TC | 56 -6 | 0.779 -0.08 | 56.1 -12.9 | 2.5 = | 93.5 -2.7 | usable | 100 W vs 250 W: lower power handling | + |
| Siemens KL405 | 75.8 +13.8 | 0.77 -0.09 | 68 -1 | 3 +0.5 | 99.2 +3 | usable | + | |
| Fonestar FPW 350 | 52 -10 | 0.876 +0.02 | 65 -4 | 3.7 +1.2 | 91.8 -4.4 | usable | 175 W vs 250 W: lower power handling | + |
| Fostex PS 300 | 58 -4 | 0.857 = | 102.2 +33.2 | 1.9 -0.6 | 95.8 -0.4 | usable | 75 W vs 250 W: lower power handling · Xmax 1.9 mm < 2.5 mm: lower excursion-limited SPL | + |
| Celestion F12M-150 Triple Cone | 69.4 +7.4 | 0.906 +0.05 | 46.9 -22.1 | 2.3 -0.2 | 95.2 -1 | usable | 150 W vs 250 W: lower power handling · Xmax 2.3 mm < 2.5 mm: lower excursion-limited SPL | + |
Comparer les 3 plus proches avec le TF 1215 →
Classé par similarité de paramètres uniquement (Qts, Fs, Vas, Xmax, sensibilité). Même taille nominale requise. Une indication, pas une simulation, modélisez l'échange avant de couper ou d'acheter.
Utilisé dans les caissons (0)
No enclosure in the catalog uses this driver yet.