Celestion K12-100 vp
Paramètres Thiele-Small
| Taille nominale | 12" |
|---|---|
| Impédance | 8 Ω |
| Fs | 61.8 Hz |
| Qts | 0.348 |
| Qes | 0.386 |
| Qms | 3.52 |
| Vas | 129.1 L |
| Sd | 615.8 cm² |
| Xmax | 2 mm |
| Re | 5.73 Ω |
| Bl | 12.5 T·m |
| Mms | 27.3 g |
| Pe | 100 W |
| Sensibilité | 102.4 dB |
Indication d'alignement
| EBP | 160 · ported |
|---|---|
| Sealed Vb (Qtc ≈ 0.71) | ≈ 41.3 L |
EBP > 100 : favorise un alignement bass-reflex.
Rules of thumb from T/S parameters only. Verify against a real simulation before cutting wood.
Candidats de substitution
| HP | Fs (Hz) | Qts | Vas (L) | Xmax (mm) | Sens (dB) | Adéquation | Notes | Comparer |
|---|---|---|---|---|---|---|---|---|
| Supravox 285-2000 MK2 | 60 -1.8 | 0.306 -0.04 | 135 +5.9 | 2.7 +0.7 | 102.5 +0.1 | close | 45 W vs 100 W: lower power handling | + |
| Supravox 285 GMF vp7 | 56.3 -5.5 | 0.369 +0.02 | 137.5 +8.4 | 3.8 +1.8 | 100.9 -1.5 | close | 70 W vs 100 W: lower power handling | + |
| Browell 12.060K | 60 -1.8 | 0.315 -0.03 | 116.6 -12.5 | 1.5 -0.5 | 101.9 -0.5 | usable | 50 W vs 100 W: lower power handling · Xmax 1.5 mm < 2 mm: lower excursion-limited SPL | + |
| Supravox 285 GMF vp8 | 52.2 -9.6 | 0.349 = | 152.5 +23.4 | 4 +2 | 100.7 -1.7 | usable | 70 W vs 100 W: lower power handling | + |
| Supravox 285 GMF vp Melaudia | 59.3 -2.5 | 0.375 +0.03 | 97.4 -31.7 | 3.3 +1.3 | 100.1 -2.3 | usable | 70 W vs 100 W: lower power handling | + |
| Radian 5312 vp | 57.9 -3.9 | 0.36 +0.01 | 101.3 -27.8 | 5.5 +3.5 | 100.4 -2 | usable | + | |
| Audax PR300T4 | 50 -11.8 | 0.357 +0.01 | 117 -12.1 | 4 +2 | 105 +2.6 | usable | 2 Ω vs 8 Ω: amp load changes | + |
| B&C 12 PH 32 (prodance) | 56.8 -5 | 0.333 -0.01 | 92.7 -36.4 | 3 +1 | 100.3 -2.1 | usable | + | |
| Supravox 285 GMF vp wowo | 50.2 -11.6 | 0.323 -0.02 | 143 +13.9 | 3.7 +1.7 | 100.2 -2.2 | usable | 70 W vs 100 W: lower power handling | + |
| Supravox 285 GMF vp4 | 50.1 -11.7 | 0.335 -0.01 | 151 +21.9 | 3.9 +1.9 | 100.2 -2.2 | usable | 70 W vs 100 W: lower power handling | + |
Comparer les 3 plus proches avec le K12-100 vp →
Classé par similarité de paramètres uniquement (Qts, Fs, Vas, Xmax, sensibilité). Même taille nominale requise. Une indication, pas une simulation, modélisez l'échange avant de couper ou d'acheter.
Utilisé dans les caissons (0)
No enclosure in the catalog uses this driver yet.