Celestion G10-GB
Paramètres Thiele-Small
| Taille nominale | 10" |
|---|---|
| Impédance | 8 Ω |
| Fs | 93.8 Hz |
| Qts | 1.398 |
| Qes | 1.748 |
| Qms | 6.992 |
| Vas | 33 L |
| Sd | 323.7 cm² |
| Xmax | 1 mm |
| Re | 6.4 Ω |
| Bl | 5.3 T·m |
| Mms | 12.8 g |
| Pe | 30 W |
| Sensibilité | 94.9 dB |
Indication d'alignement
| EBP | 54 · flexible |
|---|---|
| Sealed Vb (Qtc ≈ 0.71) | Qts too high |
EBP 50-100 : fonctionne en clos ou en bass-reflex.
Rules of thumb from T/S parameters only. Verify against a real simulation before cutting wood.
Candidats de substitution
| HP | Fs (Hz) | Qts | Vas (L) | Xmax (mm) | Sens (dB) | Adéquation | Notes | Comparer |
|---|---|---|---|---|---|---|---|---|
| Jensen CR10 | 96 +2.2 | 1.435 +0.04 | 29.7 -3.3 | 0.8 -0.2 | 94.8 -0.1 | close | Xmax 0.8 mm < 1 mm: lower excursion-limited SPL | + |
| Beyma 10AGN | 90 -3.8 | 1.319 -0.08 | 30 -3 | 1.6 +0.6 | 93 -1.9 | close | + | |
| Jensen P10R | 97 +3.2 | 1.46 +0.06 | 27.4 -5.6 | 0.8 -0.2 | 94.6 -0.3 | close | Xmax 0.8 mm < 1 mm: lower excursion-limited SPL | + |
| SICA LP 266.25 / 280 ER 4 | 75 -18.8 | 1.311 -0.09 | 40.6 +7.6 | 1.5 +0.5 | 96.9 +2 | usable | 4 Ω vs 8 Ω: amp load changes | + |
| Jensen JCH 1035-8 | 107 +13.2 | 1.435 +0.04 | 22.4 -10.6 | 0.9 -0.1 | 98.2 +3.3 | usable | 4 Ω vs 8 Ω: amp load changes · Xmax 0.9 mm < 1 mm: lower excursion-limited SPL | + |
| SICA 10 D 1 CS | 76.1 -17.7 | 1.564 +0.17 | 43.9 +10.9 | 1.5 +0.5 | 93.2 -1.7 | usable | + | |
| Jinwey YDA-250-4 | 58.3 -35.5 | 1.291 -0.11 | 36.6 +3.6 | 2 +1 | 92.2 -2.7 | usable | 4 Ω vs 8 Ω: amp load changes | + |
| Eminence LEGEND 1058 | 97 +3.2 | 1.133 -0.26 | 26.4 -6.6 | 0.5 -0.5 | 95.3 +0.4 | usable | Xmax 0.5 mm < 1 mm: lower excursion-limited SPL | + |
| Jinwey YDA-250-8 | 60.1 -33.7 | 1.473 +0.08 | 35.8 +2.8 | 1.9 +0.9 | 89 -5.9 | usable | + | |
| Celestion TF 1015 | 85 -8.8 | 1.049 -0.35 | 21 -12 | 1.4 +0.4 | 92.9 -2 | usable | + |
Comparer les 3 plus proches avec le G10-GB →
Classé par similarité de paramètres uniquement (Qts, Fs, Vas, Xmax, sensibilité). Même taille nominale requise. Une indication, pas une simulation, modélisez l'échange avant de couper ou d'acheter.
Utilisé dans les caissons (0)
No enclosure in the catalog uses this driver yet.