← tous les HP

Celestion CF1840JD

18" · 8 Ω · 1800 W · 96.8 dB · datasheet ↗

Paramètres Thiele-Small

Taille nominale18"
Impédance8 Ω
Fs44.2 Hz
Qts0.444
Qes0.496
Qms4.21
Vas113.9 L
Sd1130 cm²
Xmax8.5 mm
Re5.29 Ω
Bl24.6 T·m
Mms203.7 g
Pe1800 W
Sensibilité96.8 dB

Indication d'alignement

EBP89 · flexible
Sealed Vb (Qtc ≈ 0.71)≈ 74.1 L

EBP 50-100 : fonctionne en clos ou en bass-reflex.

Rules of thumb from T/S parameters only. Verify against a real simulation before cutting wood.

Candidats de substitution

HPFs (Hz)QtsVas (L)Xmax (mm)Sens (dB)AdéquationNotesComparer
Selenium VULCANO 3.8 18SWV3.847.4 +3.20.5 +0.06100.1 -13.811 +2.594.8 -2usable4 Ω vs 8 Ω: amp load changes+
Sica 18 PF 438 -6.20.43 -0.01147.3 +33.48 -0.596.3 -0.5usable1200 W vs 1800 W: lower power handling · Xmax 8 mm < 8.5 mm: lower excursion-limited SPL+
LaVoce SAF184.0238 -6.20.422 -0.02150 +36.18.1 -0.496.9 +0.1usable1200 W vs 1800 W: lower power handling · Xmax 8.1 mm < 8.5 mm: lower excursion-limited SPL+
Beyma 18P1200Nd vp143.8 -0.40.376 -0.07116.9 +36.1 -2.498 +1.2usable1200 W vs 1800 W: lower power handling · Xmax 6.1 mm < 8.5 mm: lower excursion-limited SPL+
DAS Audio 18SX39.2 -50.443 =171.9 +588 -0.596.4 -0.4usable1000 W vs 1800 W: lower power handling · Xmax 8 mm < 8.5 mm: lower excursion-limited SPL+
LaVoce SAN184.0238 -6.20.406 -0.04150 +36.17.9 -0.696.8 =usable1200 W vs 1800 W: lower power handling · Xmax 7.9 mm < 8.5 mm: lower excursion-limited SPL+
LaVoce SAF184.0437 -7.20.474 +0.03143 +29.19.3 +0.895.2 -1.6usable+
Beyma 18P1200Nd vp45943.8 -0.40.376 -0.07124.9 +116.3 -2.298.3 +1.5usable1200 W vs 1800 W: lower power handling · Xmax 6.3 mm < 8.5 mm: lower excursion-limited SPL+
PRV Audio 18SW300043.7 -0.50.342 -0.1111.3 -2.66.7 -1.898.1 +1.3usableXmax 6.7 mm < 8.5 mm: lower excursion-limited SPL+
JBL 18SWT3000(TORNADO)41 -3.20.55 +0.11126 +12.110.6 +2.193.7 -3.1usable4 Ω vs 8 Ω: amp load changes+

Comparer les 3 plus proches avec le CF1840JD →

Classé par similarité de paramètres uniquement (Qts, Fs, Vas, Xmax, sensibilité). Même taille nominale requise. Une indication, pas une simulation, modélisez l'échange avant de couper ou d'acheter.

Utilisé dans les caissons (0)

No enclosure in the catalog uses this driver yet.