Celestion CF1025C
Paramètres Thiele-Small
| Taille nominale | 10" |
|---|---|
| Impédance | 8 Ω |
| Fs | 54.8 Hz |
| Qts | 0.265 |
| Qes | 0.299 |
| Qms | 2.338 |
| Vas | 38.6 L |
| Sd | 346.4 cm² |
| Xmax | 2.5 mm |
| Re | 5.15 Ω |
| Bl | 14.8 T·m |
| Mms | 36.7 g |
| Pe | 300 W |
| Sensibilité | 97.2 dB |
Indication d'alignement
| EBP | 183 · ported |
|---|---|
| Sealed Vb (Qtc ≈ 0.71) | ≈ 6.3 L |
EBP > 100 : favorise un alignement bass-reflex.
Rules of thumb from T/S parameters only. Verify against a real simulation before cutting wood.
Candidats de substitution
| HP | Fs (Hz) | Qts | Vas (L) | Xmax (mm) | Sens (dB) | Adéquation | Notes | Comparer |
|---|---|---|---|---|---|---|---|---|
| RCF MB 10N251 | 55 +0.2 | 0.271 +0.01 | 38.8 +0.2 | 4.6 +2.1 | 97.4 +0.2 | close | + | |
| Ciare PW252 | 55 +0.2 | 0.264 = | 43.4 +4.8 | 2.3 -0.2 | 97 -0.2 | close | 150 W vs 300 W: lower power handling · Xmax 2.3 mm < 2.5 mm: lower excursion-limited SPL | + |
| B&C 10 PS 26 (prodance) | 53.4 -1.4 | 0.267 = | 39.5 +0.9 | 5.4 +2.9 | 96.8 -0.4 | close | + | |
| SICA 10 F 2.5 CP | 52.4 -2.4 | 0.259 -0.01 | 41.4 +2.8 | 3.4 +0.9 | 96.8 -0.4 | close | 150 W vs 300 W: lower power handling | + |
| PHL Audio 3430 | 57 +2.2 | 0.271 +0.01 | 41 +2.4 | 4.2 +1.7 | 97.7 +0.5 | close | + | |
| Fane SOVEREIGN PRO 10M | 56 +1.2 | 0.27 +0.01 | 37 -1.6 | 2 -0.5 | 97.1 -0.1 | close | Xmax 2 mm < 2.5 mm: lower excursion-limited SPL | + |
| P.Audio E10-200S v2011 | 55.4 +0.6 | 0.272 +0.01 | 44.6 +6 | 4 +1.5 | 96.9 -0.3 | close | 200 W vs 300 W: lower power handling | + |
| SICA 10 K 3 PL 8 Ohms v2017 | 50.6 -4.2 | 0.256 -0.01 | 40 +1.4 | 4 +1.5 | 96.7 -0.5 | close | + | |
| PHL Audio 3001 | 57 +2.2 | 0.282 +0.02 | 35 -3.6 | 3.5 +1 | 97 -0.2 | close | 200 W vs 300 W: lower power handling | + |
| PHL Audio 3420 | 53 -1.8 | 0.256 -0.01 | 35 -3.6 | 4.3 +1.8 | 97.6 +0.4 | close | + |
Comparer les 3 plus proches avec le CF1025C →
Classé par similarité de paramètres uniquement (Qts, Fs, Vas, Xmax, sensibilité). Même taille nominale requise. Une indication, pas une simulation, modélisez l'échange avant de couper ou d'acheter.
Utilisé dans les caissons (0)
No enclosure in the catalog uses this driver yet.