Paramètres Thiele-Small
| Taille nominale | 15" |
|---|---|
| Impédance | 8 Ω |
| Fs | 44.9 Hz |
| Qts | 0.59 |
| Qes | 0.72 |
| Qms | 3.27 |
| Vas | 146.5 L |
| Sd | 854.9 cm² |
| Xmax | 4 mm |
| Re | 5.34 Ω |
| Bl | 13.6 T·m |
| Mms | 87.9 g |
| Pe | 400 W |
| Sensibilité | 96.4 dB |
Indication d'alignement
| EBP | 62 · flexible |
|---|---|
| Sealed Vb (Qtc ≈ 0.71) | ≈ 335.7 L |
EBP 50-100 : fonctionne en clos ou en bass-reflex.
Rules of thumb from T/S parameters only. Verify against a real simulation before cutting wood.
Candidats de substitution
| HP | Fs (Hz) | Qts | Vas (L) | Xmax (mm) | Sens (dB) | Adéquation | Notes | Comparer |
|---|---|---|---|---|---|---|---|---|
| Celestion BN15-300X | 45.9 +1 | 0.603 +0.01 | 153.4 +6.9 | 4 = | 96.7 +0.3 | close | 300 W vs 400 W: lower power handling | + |
| SB Audience BIANCO-15MW200 | 44 -0.9 | 0.586 = | 153 +6.5 | 5.2 +1.2 | 96 -0.4 | close | 200 W vs 400 W: lower power handling | + |
| SICA 15 BS 2.5 PL | 44 -0.9 | 0.552 -0.04 | 160 +13.5 | 4 = | 97.5 +1.1 | close | 250 W vs 400 W: lower power handling | + |
| LaVoce WSF152.50 | 46 +1.1 | 0.505 -0.08 | 137 -9.5 | 4.7 +0.7 | 97.3 +0.9 | close | 250 W vs 400 W: lower power handling | + |
| Faital PRO 15FH520 | 42 -2.9 | 0.62 +0.03 | 134.2 -12.3 | 9 +5 | 97 +0.6 | close | 16 Ω vs 8 Ω: amp load changes | + |
| Celestion BL15-150 | 49 +4.1 | 0.593 = | 179.8 +33.3 | 4.3 +0.3 | 98.4 +2 | close | 150 W vs 400 W: lower power handling | + |
| JB Systems PWX15-300 | 40.1 -4.8 | 0.552 -0.04 | 169.9 +23.4 | 5 +1 | 96 -0.4 | close | 300 W vs 400 W: lower power handling | + |
| DAP Audio AB-15 | 46.7 +1.8 | 0.546 -0.04 | 122.3 -24.2 | 5.5 +1.5 | 95.4 -1 | close | + | |
| Eminence DELTA 15 LF | 41 -3.9 | 0.584 -0.01 | 186.1 +39.6 | 6 +2 | 96 -0.4 | close | + | |
| Fane SOVEREIGN 15-250 | 43 -1.9 | 0.728 +0.14 | 144 -2.5 | 4.4 +0.4 | 94.6 -1.8 | close | 250 W vs 400 W: lower power handling | + |
Comparer les 3 plus proches avec le BN15-400X →
Classé par similarité de paramètres uniquement (Qts, Fs, Vas, Xmax, sensibilité). Même taille nominale requise. Une indication, pas une simulation, modélisez l'échange avant de couper ou d'acheter.
Utilisé dans les caissons (0)
No enclosure in the catalog uses this driver yet.