BMS 6S117
Paramètres Thiele-Small
| Taille nominale | 6" |
|---|---|
| Impédance | 16 Ω |
| Fs | 80 Hz |
| Qts | 0.43 |
| Qes | 0.49 |
| Qms | 3.3 |
| Vas | 10.4 L |
| Sd | 143 cm² |
| Xmax | 5 mm |
| Re | 11.4 Ω |
| Bl | 11.3 T·m |
| Mms | 11 g |
| Pe | 130 W |
| Sensibilité | 93 dB |
Indication d'alignement
| EBP | 163 · ported |
|---|---|
| Sealed Vb (Qtc ≈ 0.71) | ≈ 6.1 L |
EBP > 100 : favorise un alignement bass-reflex.
Rules of thumb from T/S parameters only. Verify against a real simulation before cutting wood.
Candidats de substitution
| HP | Fs (Hz) | Qts | Vas (L) | Xmax (mm) | Sens (dB) | Adéquation | Notes | Comparer |
|---|---|---|---|---|---|---|---|---|
| BMS 6N160 | 89 +9 | 0.47 +0.04 | 7.7 -2.7 | 5 = | 93 = | usable | + | |
| Faital PRO 6RS140 | 65 -15 | 0.36 -0.07 | 9.9 -0.5 | 5.5 +0.5 | 92 -1 | usable | + | |
| LaVoce WAF061.80 | 65 -15 | 0.42 -0.01 | 7.26 -3.14 | 4.9 -0.1 | 91 -2 | usable | 8 Ω vs 16 Ω: amp load changes · Xmax 4.9 mm < 5 mm: lower excursion-limited SPL | + |
| LaVoce WAN061.80-16 | 62 -18 | 0.31 -0.12 | 10.26 -0.14 | 5.2 +0.2 | 92.5 -0.5 | usable | + | |
| LaVoce WSF061.52-16 | 93 +13 | 0.42 -0.01 | 6.92 -3.48 | 3.7 -1.3 | 93.5 +0.5 | usable | Xmax 3.7 mm < 5 mm: lower excursion-limited SPL | + |
| Sica 6 N 2 PL | 68 -12 | 0.33 -0.1 | 8.7 -1.7 | 3.5 -1.5 | 92.3 -0.7 | usable | 8 Ω vs 16 Ω: amp load changes · Xmax 3.5 mm < 5 mm: lower excursion-limited SPL | + |
| Faital PRO 6RS140 | 65 -15 | 0.27 -0.16 | 9.3 -1.1 | 5.6 +0.6 | 93 = | usable | 8 Ω vs 16 Ω: amp load changes | + |
| Sica 6 NR 2 PL | 60.5 -19.5 | 0.33 -0.1 | 9.4 -1 | 4 -1 | 91.4 -1.6 | usable | 8 Ω vs 16 Ω: amp load changes · Xmax 4 mm < 5 mm: lower excursion-limited SPL | + |
| LaVoce WSN061.52 | 90 +10 | 0.39 -0.04 | 5.92 -4.48 | 3.8 -1.2 | 94 +1 | usable | 8 Ω vs 16 Ω: amp load changes · Xmax 3.8 mm < 5 mm: lower excursion-limited SPL | + |
| LaVoce WAN061.80 | 60 -20 | 0.27 -0.16 | 11.18 +0.78 | 5.2 +0.2 | 93 = | usable | 8 Ω vs 16 Ω: amp load changes | + |
Comparer les 3 plus proches avec le 6S117 →
Classé par similarité de paramètres uniquement (Qts, Fs, Vas, Xmax, sensibilité). Même taille nominale requise. Une indication, pas une simulation, modélisez l'échange avant de couper ou d'acheter.
Utilisé dans les caissons (0)
No enclosure in the catalog uses this driver yet.