BMS 15N830V2
Paramètres Thiele-Small
| Taille nominale | 15" |
|---|---|
| Impédance | 6 Ω |
| Fs | 39.5 Hz |
| Qts | 0.27 |
| Qes | 0.29 |
| Qms | 4.2 |
| Vas | 159 L |
| Sd | 880 cm² |
| Xmax | 8 mm |
| Re | 4.5 Ω |
| Bl | 22.4 T·m |
| Mms | 130 g |
| Pe | 550 W |
| Sensibilité | 97.1 dB |
Indication d'alignement
| EBP | 136 · ported |
|---|---|
| Sealed Vb (Qtc ≈ 0.71) | ≈ 27.1 L |
EBP > 100 : favorise un alignement bass-reflex.
Rules of thumb from T/S parameters only. Verify against a real simulation before cutting wood.
Candidats de substitution
| HP | Fs (Hz) | Qts | Vas (L) | Xmax (mm) | Sens (dB) | Adéquation | Notes | Comparer |
|---|---|---|---|---|---|---|---|---|
| 18 Sound 15NLW9300 | 39 -0.5 | 0.26 -0.01 | 170 +11 | 8 = | 97 -0.1 | close | 8 Ω vs 6 Ω: amp load changes | + |
| BMS 15N830vv2 | 37 -2.5 | 0.27 = | 159 = | 8 = | 96 -1.1 | close | 8 Ω vs 6 Ω: amp load changes | + |
| BMS 15N830V2 v2015 | 37 -2.5 | 0.271 = | 159 = | 7.5 -0.5 | 98.6 +1.5 | close | 8 Ω vs 6 Ω: amp load changes · Xmax 7.5 mm < 8 mm: lower excursion-limited SPL | + |
| B&C 15NDL88 | 41 +1.5 | 0.28 +0.01 | 154 -5 | 8 = | 99 +1.9 | close | 4 Ω vs 6 Ω: amp load changes | + |
| SICA 15 K3 PL-8 | 40 +0.5 | 0.27 = | 166.1 +7.1 | 6.5 -1.5 | 97.6 +0.5 | close | 8 Ω vs 6 Ω: amp load changes · 400 W vs 550 W: lower power handling · Xmax 6.5 mm < 8 mm: lower excursion-limited SPL | + |
| RCF LF15G401 | 36 -3.5 | 0.26 -0.01 | 150 -9 | 9 +1 | 97 -0.1 | close | 8 Ω vs 6 Ω: amp load changes | + |
| RCF LF15Y408 | 36 -3.5 | 0.26 -0.01 | 150 -9 | 9 +1 | 97 -0.1 | close | 8 Ω vs 6 Ω: amp load changes | + |
| Fane COLOSSUS 15XBN | 38 -1.5 | 0.279 +0.01 | 168 +9 | 7.5 -0.5 | 98.1 +1 | close | 8 Ω vs 6 Ω: amp load changes · Xmax 7.5 mm < 8 mm: lower excursion-limited SPL | + |
| 18 Sound 15ND940 | 39 -0.5 | 0.26 -0.01 | 170 +11 | 9.5 +1.5 | 99 +1.9 | close | 4 Ω vs 6 Ω: amp load changes | + |
| RCF L15P400 | 36 -3.5 | 0.25 -0.02 | 160 +1 | 8 = | 96.3 -0.8 | close | 8 Ω vs 6 Ω: amp load changes · 400 W vs 550 W: lower power handling | + |
Comparer les 3 plus proches avec le 15N830V2 →
Classé par similarité de paramètres uniquement (Qts, Fs, Vas, Xmax, sensibilité). Même taille nominale requise. Une indication, pas une simulation, modélisez l'échange avant de couper ou d'acheter.
Utilisé dans les caissons (0)
No enclosure in the catalog uses this driver yet.