← tous les HP

Beyma SM212 v2009

12" · 8 Ω · 350 W · 97.2 dB · datasheet ↗

Paramètres Thiele-Small

Taille nominale12"
Impédance8 Ω
Fs40 Hz
Qts0.373
Qes0.4
Qms5.6
Vas150 L
Sd550 cm²
Xmax8.2 mm
Re5.8 Ω
Bl12.8 T·m
Mms44.8 g
Pe350 W
Sensibilité97.2 dB

Indication d'alignement

EBP100 · flexible
Sealed Vb (Qtc ≈ 0.71)≈ 57.8 L

EBP 50-100 : fonctionne en clos ou en bass-reflex.

Rules of thumb from T/S parameters only. Verify against a real simulation before cutting wood.

Candidats de substitution

HPFs (Hz)QtsVas (L)Xmax (mm)Sens (dB)AdéquationNotesComparer
Faital PRO 12PR32042 +20.37 =113.3 -36.77.37 -0.8397 -0.2closeXmax 7.37 mm < 8.2 mm: lower excursion-limited SPL+
Faital PRO 12PR320-08 v202242 +20.371 =113 -377.1 -1.197.1 -0.1closeXmax 7.1 mm < 8.2 mm: lower excursion-limited SPL+
Infinity KAPPA CS 120 BR35.2 -4.80.397 +0.02123.2 -26.88 -0.297.1 -0.1close4 Ω vs 8 Ω: amp load changes · 250 W vs 350 W: lower power handling · Xmax 8 mm < 8.2 mm: lower excursion-limited SPL+
Ardan W PRO-3136.8 -3.20.373 =133.9 -16.16 -2.294.6 -2.6usable200 W vs 350 W: lower power handling · Xmax 6 mm < 8.2 mm: lower excursion-limited SPL+
Eminence DELTALITE II 2512 v237 -30.386 +0.01147 -34.9 -3.396.3 -0.9usable250 W vs 350 W: lower power handling · Xmax 4.9 mm < 8.2 mm: lower excursion-limited SPL+
Eminence DELTA PRO 12-450A44 +40.371 =141.7 -8.35.2 -398.9 +1.7usableXmax 5.2 mm < 8.2 mm: lower excursion-limited SPL+
Beyma SM212-N243 +30.372 =103 -476.9 -1.396.7 -0.5usableXmax 6.9 mm < 8.2 mm: lower excursion-limited SPL+
Beyma SM212 v201843 +30.381 +0.01103 -477 -1.296.6 -0.6usableXmax 7 mm < 8.2 mm: lower excursion-limited SPL+
Beyma SM212 vp N&ordm;241.7 +1.70.41 +0.04110.7 -39.37.3 -0.995.2 -2usableXmax 7.3 mm < 8.2 mm: lower excursion-limited SPL+
Beyma SM112/N38 -20.27 -0.1138 -127.3 -0.997.2 =usableXmax 7.3 mm < 8.2 mm: lower excursion-limited SPL+

Comparer les 3 plus proches avec le SM212 v2009 →

Classé par similarité de paramètres uniquement (Qts, Fs, Vas, Xmax, sensibilité). Même taille nominale requise. Une indication, pas une simulation, modélisez l'échange avant de couper ou d'acheter.

Utilisé dans les caissons (0)

No enclosure in the catalog uses this driver yet.