Beyma 6P200Fe
Paramètres Thiele-Small
| Taille nominale | 6.5" |
|---|---|
| Impédance | 16 Ω |
| Fs | 66 Hz |
| Qts | 0.35 |
| Qes | 0.38 |
| Qms | 4.3 |
| Vas | 8.8 L |
| Sd | 135 cm² |
| Xmax | 4 mm |
| Re | 9.9 Ω |
| Bl | 13.6 T·m |
| Mms | 16 g |
| Pe | 200 W |
| Sensibilité | 93 dB |
Indication d'alignement
| EBP | 174 · ported |
|---|---|
| Sealed Vb (Qtc ≈ 0.71) | ≈ 2.9 L |
EBP > 100 : favorise un alignement bass-reflex.
Rules of thumb from T/S parameters only. Verify against a real simulation before cutting wood.
Candidats de substitution
| HP | Fs (Hz) | Qts | Vas (L) | Xmax (mm) | Sens (dB) | Adéquation | Notes | Comparer |
|---|---|---|---|---|---|---|---|---|
| B&C 6PS44 | 71 +5 | 0.33 -0.02 | 7 -1.8 | 4.5 +0.5 | 93 = | close | 8 Ω vs 16 Ω: amp load changes | + |
| Oberton 6NB150 | 62.32 -3.68 | 0.28 -0.07 | 9.3 +0.5 | 5.5 +1.5 | 92 -1 | usable | 8 Ω vs 16 Ω: amp load changes · 150 W vs 200 W: lower power handling | + |
| B&C 6PS38 | 75 +9 | 0.3 -0.05 | 8 -0.8 | 6 +2 | 94 +1 | usable | 8 Ω vs 16 Ω: amp load changes · 150 W vs 200 W: lower power handling | + |
| B&C 6NDL38 | 69 +3 | 0.39 +0.04 | 7.1 -1.7 | 6 +2 | 91 -2 | usable | 4 Ω vs 16 Ω: amp load changes · 150 W vs 200 W: lower power handling | + |
| 18 Sound 6ND430 | 66 = | 0.3 -0.05 | 12.6 +3.8 | 5 +1 | 94 +1 | usable | + | |
| B&C 6NDL38 | 70 +4 | 0.5 +0.15 | 8.9 +0.1 | 6 +2 | 93 = | usable | 150 W vs 200 W: lower power handling | + |
| B&C 6NDL38 | 72 +6 | 0.42 +0.07 | 7 -1.8 | 6 +2 | 92 -1 | usable | 8 Ω vs 16 Ω: amp load changes · 150 W vs 200 W: lower power handling | + |
| Beyma 6CMV2 | 90 +24 | 0.34 -0.01 | 6.5 -2.3 | 5.7 +1.7 | 94 +1 | usable | 8 Ω vs 16 Ω: amp load changes | + |
| Beyma 6P200Fe | 58 -8 | 0.26 -0.09 | 11.1 +2.3 | 5 +1 | 93 = | usable | 8 Ω vs 16 Ω: amp load changes | + |
| Beyma 6"P200/ND | 56 -10 | 0.29 -0.06 | 11.9 +3.1 | 5.5 +1.5 | 92 -1 | usable | 8 Ω vs 16 Ω: amp load changes | + |
Comparer les 3 plus proches avec le 6P200Fe →
Classé par similarité de paramètres uniquement (Qts, Fs, Vas, Xmax, sensibilité). Même taille nominale requise. Une indication, pas une simulation, modélisez l'échange avant de couper ou d'acheter.
Utilisé dans les caissons (0)
No enclosure in the catalog uses this driver yet.