Beyma 18PWB1000/FE v2016
Paramètres Thiele-Small
| Taille nominale | 18" |
|---|---|
| Impédance | 8 Ω |
| Fs | 27 Hz |
| Qts | 0.381 |
| Qes | 0.4 |
| Qms | 8.2 |
| Vas | 317 L |
| Sd | 1255 cm² |
| Xmax | 11.7 mm |
| Re | 6 Ω |
| Bl | 24.8 T·m |
| Mms | 242 g |
| Pe | 1000 W |
| Sensibilité | 95.2 dB |
Indication d'alignement
| EBP | 68 · flexible |
|---|---|
| Sealed Vb (Qtc ≈ 0.71) | ≈ 129.7 L |
EBP 50-100 : fonctionne en clos ou en bass-reflex.
Rules of thumb from T/S parameters only. Verify against a real simulation before cutting wood.
Candidats de substitution
| HP | Fs (Hz) | Qts | Vas (L) | Xmax (mm) | Sens (dB) | Adéquation | Notes | Comparer |
|---|---|---|---|---|---|---|---|---|
| Beyma 18PWB1000Fe/S | 27 = | 0.38 = | 317 = | 12.5 +0.8 | 96 +0.8 | close | + | |
| BMS 18N862 vp | 24.8 -2.2 | 0.383 = | 345.6 +28.6 | 16.2 +4.5 | 94.8 -0.4 | close | + | |
| BMS 18N860 | 24 -3 | 0.372 -0.01 | 304 -13 | 15 +3.3 | 93.7 -1.5 | close | + | |
| BMS 18N862 | 25.1 -1.9 | 0.34 -0.04 | 312 -5 | 19 +7.3 | 95 -0.2 | close | + | |
| Magnat AGRESSOR 5000 | 24 -3 | 0.431 +0.05 | 324 +7 | 10.6 -1.1 | 95.3 +0.1 | close | 4 Ω vs 8 Ω: amp load changes · Xmax 10.6 mm < 11.7 mm: lower excursion-limited SPL | + |
| AER SB 18 | 26 -1 | 0.383 = | 288 -29 | 8.3 -3.4 | 94.5 -0.7 | close | 500 W vs 1000 W: lower power handling · Xmax 8.3 mm < 11.7 mm: lower excursion-limited SPL | + |
| Beyma 18G550 (prodance) | 29.5 +2.5 | 0.382 = | 291 -26 | 9 -2.7 | 96.7 +1.5 | close | Xmax 9 mm < 11.7 mm: lower excursion-limited SPL | + |
| Fane COLOSSUS PRIME 18XS | 33 +6 | 0.385 = | 257 -60 | 12 +0.3 | 95.4 +0.2 | close | + | |
| JBL 2269H | 28 +1 | 0.361 -0.02 | 237 -80 | 10.6 -1.1 | 95 -0.2 | close | Xmax 10.6 mm < 11.7 mm: lower excursion-limited SPL | + |
| Dayton Audio APOLLO 18F | 32 +5 | 0.401 +0.02 | 287.7 -29.3 | 10.6 -1.1 | 96.4 +1.2 | usable | Xmax 10.6 mm < 11.7 mm: lower excursion-limited SPL | + |
Comparer les 3 plus proches avec le 18PWB1000/FE v2016 →
Classé par similarité de paramètres uniquement (Qts, Fs, Vas, Xmax, sensibilité). Même taille nominale requise. Une indication, pas une simulation, modélisez l'échange avant de couper ou d'acheter.
Utilisé dans les caissons (0)
No enclosure in the catalog uses this driver yet.