Beyma 15MC700
Paramètres Thiele-Small
| Taille nominale | 15" |
|---|---|
| Impédance | 8 Ω |
| Fs | 41 Hz |
| Qts | 0.352 |
| Qes | 0.38 |
| Qms | 4.8 |
| Vas | 153 L |
| Sd | 880 cm² |
| Xmax | 7.4 mm |
| Re | 5.9 Ω |
| Bl | 20.7 T·m |
| Mms | 106.9 g |
| Pe | 700 W |
| Sensibilité | 97.7 dB |
Indication d'alignement
| EBP | 108 · ported |
|---|---|
| Sealed Vb (Qtc ≈ 0.71) | ≈ 50.4 L |
EBP > 100 : favorise un alignement bass-reflex.
Rules of thumb from T/S parameters only. Verify against a real simulation before cutting wood.
Candidats de substitution
| HP | Fs (Hz) | Qts | Vas (L) | Xmax (mm) | Sens (dB) | Adéquation | Notes | Comparer |
|---|---|---|---|---|---|---|---|---|
| Eminence KILOMAX 15 | 41 = | 0.383 +0.03 | 154 +1 | 7.9 +0.5 | 98.3 +0.6 | close | + | |
| Eminence KILOMAX PRO 15 | 41 = | 0.383 +0.03 | 154.5 +1.5 | 7.9 +0.5 | 98.3 +0.6 | close | + | |
| Eminence KILOMAX PRO 15 A | 41 = | 0.383 +0.03 | 154.5 +1.5 | 7.9 +0.5 | 98.3 +0.6 | close | + | |
| PD PD 15BR40 | 38.7 -2.3 | 0.34 -0.01 | 158.3 +5.3 | 7.9 +0.5 | 98.1 +0.4 | close | + | |
| Precision Devices PD 15BR40 | 38.7 -2.3 | 0.34 -0.01 | 158.3 +5.3 | 7.9 +0.5 | 98.1 +0.4 | close | + | |
| 18 Sound 15ND940 | 41 = | 0.36 +0.01 | 166 +13 | 9.5 +2.1 | 98.5 +0.8 | close | 16 Ω vs 8 Ω: amp load changes | + |
| 18 Sound 15ND830 | 42 +1 | 0.34 -0.01 | 157 +4 | 6.5 -0.9 | 98 +0.3 | close | 4 Ω vs 8 Ω: amp load changes · 450 W vs 700 W: lower power handling · Xmax 6.5 mm < 7.4 mm: lower excursion-limited SPL | + |
| Faital PRO 15FH500 vp3 | 40.8 -0.2 | 0.343 -0.01 | 141.8 -11.2 | 6.7 -0.7 | 98.2 +0.5 | close | 500 W vs 700 W: lower power handling · Xmax 6.7 mm < 7.4 mm: lower excursion-limited SPL | + |
| Faital PRO 15FH520 | 38 -3 | 0.34 -0.01 | 153.2 +0.2 | 9.15 +1.75 | 97 -0.7 | close | 4 Ω vs 8 Ω: amp load changes | + |
| P.Audio S15-100LF | 38 -3 | 0.35 = | 169.1 +16.1 | 7.8 +0.4 | 98 +0.3 | close | + |
Comparer les 3 plus proches avec le 15MC700 →
Classé par similarité de paramètres uniquement (Qts, Fs, Vas, Xmax, sensibilité). Même taille nominale requise. Une indication, pas une simulation, modélisez l'échange avant de couper ou d'acheter.
Utilisé dans les caissons (0)
No enclosure in the catalog uses this driver yet.