Beyma 15B100R
Paramètres Thiele-Small
| Taille nominale | 15" |
|---|---|
| Impédance | 8 Ω |
| Fs | 20 Hz |
| Qts | 0.14 |
| Qes | 0.32 |
| Qms | 0.25 |
| Vas | 590 L |
| Sd | 851 cm² |
| Xmax | 3 mm |
| Re | 6 Ω |
| Bl | 16 T·m |
| Mms | 109 g |
| Pe | 150 W |
| Sensibilité | 94.9 dB |
Indication d'alignement
| EBP | 63 · flexible |
|---|---|
| Sealed Vb (Qtc ≈ 0.71) | ≈ 24.1 L |
EBP 50-100 : fonctionne en clos ou en bass-reflex.
Rules of thumb from T/S parameters only. Verify against a real simulation before cutting wood.
Candidats de substitution
| HP | Fs (Hz) | Qts | Vas (L) | Xmax (mm) | Sens (dB) | Adéquation | Notes | Comparer |
|---|---|---|---|---|---|---|---|---|
| Electro-Voice DL 15W | 21 +1 | 0.164 +0.02 | 575 -15 | 5.6 +2.6 | 98.2 +3.3 | usable | + | |
| Audax PR38SM250 | 19.5 -0.5 | 0.177 +0.04 | 660 +70 | 4 +1 | 97.7 +2.8 | usable | + | |
| JBL 1501AL-1 | 19 -1 | 0.191 +0.05 | 630 +40 | 6.4 +3.4 | 94.6 -0.3 | usable | 16 Ω vs 8 Ω: amp load changes | + |
| Fertin Acoustics 38EX-2 | 25 +5 | 0.135 -0.01 | 595 +5 | 3 = | 102.2 +7.3 | usable | 80 W vs 150 W: lower power handling | + |
| Altec 515B | 24.7 +4.7 | 0.166 +0.03 | 557.8 -32.2 | 4.2 +1.2 | 97.2 +2.3 | usable | 16 Ω vs 8 Ω: amp load changes · 75 W vs 150 W: lower power handling | + |
| Altec 515C | 24.7 +4.7 | 0.166 +0.03 | 557.8 -32.2 | 4.2 +1.2 | 97.2 +2.3 | usable | 16 Ω vs 8 Ω: amp load changes · 75 W vs 150 W: lower power handling | + |
| Fluxmag 1504-DF | 21.6 +1.6 | 0.132 -0.01 | 393.2 -196.8 | 4 +1 | 98.9 +4 | usable | + | |
| Altec 515E | 22.9 +2.9 | 0.185 +0.04 | 665.5 +75.5 | 4.6 +1.6 | 96.5 +1.6 | usable | 16 Ω vs 8 Ω: amp load changes · 75 W vs 150 W: lower power handling | + |
| Tannoy K3838 | 22 +2 | 0.176 +0.04 | 481.4 -108.6 | 4 +1 | 97.9 +3 | usable | + | |
| EMS B15EX-12.5V | 22 +2 | 0.146 +0.01 | 791 +201 | 5.4 +2.4 | 100.4 +5.5 | usable | 100 W vs 150 W: lower power handling | + |
Comparer les 3 plus proches avec le 15B100R →
Classé par similarité de paramètres uniquement (Qts, Fs, Vas, Xmax, sensibilité). Même taille nominale requise. Une indication, pas une simulation, modélisez l'échange avant de couper ou d'acheter.
Utilisé dans les caissons (0)
No enclosure in the catalog uses this driver yet.