Beyma 15 XT
Paramètres Thiele-Small
| Taille nominale | 15" |
|---|---|
| Impédance | 8 Ω |
| Fs | 33 Hz |
| Qts | 0.289 |
| Qes | 0.3 |
| Qms | 7.68 |
| Vas | 270 L |
| Sd | 850 cm² |
| Xmax | 5 mm |
| Re | 6.5 Ω |
| Bl | 19.8 T·m |
| Mms | 87.3 g |
| Pe | 200 W |
| Sensibilité | 98 dB |
Indication d'alignement
| EBP | 110 · ported |
|---|---|
| Sealed Vb (Qtc ≈ 0.71) | ≈ 54.1 L |
EBP > 100 : favorise un alignement bass-reflex.
Rules of thumb from T/S parameters only. Verify against a real simulation before cutting wood.
Candidats de substitution
| HP | Fs (Hz) | Qts | Vas (L) | Xmax (mm) | Sens (dB) | Adéquation | Notes | Comparer |
|---|---|---|---|---|---|---|---|---|
| Faital PRO 15PR400 v2014 | 32 -1 | 0.295 +0.01 | 267.2 -2.8 | 5.8 +0.8 | 98.4 +0.4 | close | + | |
| Eminence OMEGA PRO 15 A | 33 = | 0.312 +0.02 | 258.5 -11.5 | 4.8 -0.2 | 98.3 +0.3 | close | Xmax 4.8 mm < 5 mm: lower excursion-limited SPL | + |
| Eminence OMEGA 15 A | 33 = | 0.312 +0.02 | 258 -12 | 4.8 -0.2 | 98.3 +0.3 | close | Xmax 4.8 mm < 5 mm: lower excursion-limited SPL | + |
| Eminence MAGNUM 15 HO | 33 = | 0.27 -0.02 | 241 -29 | 4.8 -0.2 | 97.9 -0.1 | close | Xmax 4.8 mm < 5 mm: lower excursion-limited SPL | + |
| Eminence OMEGA PRO-15A | 33 = | 0.32 +0.03 | 258.5 -11.5 | 4.8 -0.2 | 97.3 -0.7 | close | Xmax 4.8 mm < 5 mm: lower excursion-limited SPL | + |
| Faital PRO 15PR400 vp | 32.8 -0.2 | 0.332 +0.04 | 263.2 -6.8 | 5.8 +0.8 | 98 = | close | + | |
| RCF L 15/542K | 36 +3 | 0.3 +0.01 | 250 -20 | 5 = | 98.8 +0.8 | close | + | |
| JBL K145 | 35 +2 | 0.286 = | 243.5 -26.5 | 4.7 -0.3 | 97 -1 | close | 16 Ω vs 8 Ω: amp load changes · 150 W vs 200 W: lower power handling · Xmax 4.7 mm < 5 mm: lower excursion-limited SPL | + |
| Beyma 15G350 | 34 +1 | 0.293 = | 302 +32 | 4.5 -0.5 | 99 +1 | close | Xmax 4.5 mm < 5 mm: lower excursion-limited SPL | + |
| Gauss 4583A v2 | 31 -2 | 0.292 = | 283 +13 | 4 -1 | 97.9 -0.1 | close | 150 W vs 200 W: lower power handling · Xmax 4 mm < 5 mm: lower excursion-limited SPL | + |
Comparer les 3 plus proches avec le 15 XT →
Classé par similarité de paramètres uniquement (Qts, Fs, Vas, Xmax, sensibilité). Même taille nominale requise. Une indication, pas une simulation, modélisez l'échange avant de couper ou d'acheter.
Utilisé dans les caissons (0)
No enclosure in the catalog uses this driver yet.