← tous les HP

Beyma 12GA50

12" · 8 Ω · 250 W · 94.8 dB

Paramètres Thiele-Small

Taille nominale12"
Impédance8 Ω
Fs90 Hz
Qts1.16
Qes1.26
Qms14.8
Vas34 L
Sd530 cm²
Xmax2 mm
Re6.2 Ω
Bl10 T·m
Mms34 g
Pe250 W
Sensibilité94.8 dB

Indication d'alignement

EBP71 · flexible
Sealed Vb (Qtc ≈ 0.71)Qts too high

EBP 50-100 : fonctionne en clos ou en bass-reflex.

Rules of thumb from T/S parameters only. Verify against a real simulation before cutting wood.

Candidats de substitution

HPFs (Hz)QtsVas (L)Xmax (mm)Sens (dB)AdéquationNotesComparer
Visaton FR 3090 =1.284 +0.1227 -71.1 -0.993.7 -1.1usable100 W vs 250 W: lower power handling · Xmax 1.1 mm < 2 mm: lower excursion-limited SPL+
Jensen JCH 1270-878 -121.084 -0.0846.7 +12.71.5 -0.596.6 +1.8usable70 W vs 250 W: lower power handling · Xmax 1.5 mm < 2 mm: lower excursion-limited SPL+
Celestion G12T 7585 -50.836 -0.3251 +172 =95.3 +0.5usable16 Ω vs 8 Ω: amp load changes · 75 W vs 250 W: lower power handling+
Celestion F12M-150 Triple Cone69.4 -20.60.906 -0.2546.9 +12.92.3 +0.395.2 +0.4usable150 W vs 250 W: lower power handling+
Celestion G12T-10081 -90.833 -0.3347 +132 =96.8 +2usable100 W vs 250 W: lower power handling+
Jensen JP12-100BB95.1 +5.10.836 -0.3234.4 +0.41 -198.2 +3.4usable100 W vs 250 W: lower power handling · Xmax 1 mm < 2 mm: lower excursion-limited SPL+
JBL 2142H72 -180.755 -0.445.3 +11.32.2 +0.296.5 +1.7usable100 W vs 250 W: lower power handling+
Celestion F12-X20075 -150.777 -0.3847.3 +13.33 +197.1 +2.3usable+
Eminence LEGEND 125894 +40.99 -0.1732.5 -1.50.5 -1.595.9 +1.1risky75 W vs 250 W: lower power handling · Xmax 0.5 mm < 2 mm: lower excursion-limited SPL+
Eminence LEGEND 1218100 +100.895 -0.2631.2 -2.80.8 -1.297.8 +3risky150 W vs 250 W: lower power handling · Xmax 0.8 mm < 2 mm: lower excursion-limited SPL+

Comparer les 3 plus proches avec le 12GA50 →

Classé par similarité de paramètres uniquement (Qts, Fs, Vas, Xmax, sensibilité). Même taille nominale requise. Une indication, pas une simulation, modélisez l'échange avant de couper ou d'acheter.

Utilisé dans les caissons (0)

No enclosure in the catalog uses this driver yet.