Beyma 10LW30/N
Paramètres Thiele-Small
| Taille nominale | 10" |
|---|---|
| Impédance | 8 Ω |
| Fs | 38 Hz |
| Qts | 0.234 |
| Qes | 0.24 |
| Qms | 9.9 |
| Vas | 56 L |
| Sd | 350 cm² |
| Xmax | 7 mm |
| Re | 6.1 Ω |
| Bl | 18.1 T·m |
| Mms | 53.8 g |
| Pe | 450 W |
| Sensibilité | 94.2 dB |
Indication d'alignement
| EBP | 158 · ported |
|---|---|
| Sealed Vb (Qtc ≈ 0.71) | ≈ 6.9 L |
EBP > 100 : favorise un alignement bass-reflex.
Rules of thumb from T/S parameters only. Verify against a real simulation before cutting wood.
Candidats de substitution
| HP | Fs (Hz) | Qts | Vas (L) | Xmax (mm) | Sens (dB) | Adéquation | Notes | Comparer |
|---|---|---|---|---|---|---|---|---|
| AE Speakers TD10M-8 | 40.1 +2.1 | 0.238 = | 59.2 +3.2 | 6 -1 | 94.5 +0.3 | close | Xmax 6 mm < 7 mm: lower excursion-limited SPL | + |
| AE Speakers TD10M | 40.6 +2.6 | 0.235 = | 59.1 +3.1 | 6 -1 | 94.7 +0.5 | close | Xmax 6 mm < 7 mm: lower excursion-limited SPL | + |
| Eminence KAPPALITE 3010LF-4 | 40 +2 | 0.251 +0.02 | 53.5 -2.5 | 8.1 +1.1 | 96.4 +2.2 | close | 4 Ω vs 8 Ω: amp load changes | + |
| Eminence KAPPALITE 3010 LF | 38.7 +0.7 | 0.273 +0.04 | 62.4 +6.4 | 8.5 +1.5 | 93.5 -0.7 | close | + | |
| Beyma 10LW30 | 42 +4 | 0.293 +0.06 | 55 -1 | 7 = | 94.6 +0.4 | close | + | |
| AE Speakers TD10X | 35 -3 | 0.27 +0.04 | 67.5 +11.5 | 7 = | 92.4 -1.8 | usable | + | |
| Eminence KAPPA PRO 10 LF | 39 +1 | 0.281 +0.05 | 73 +17 | 7.2 +0.2 | 95.4 +1.2 | usable | + | |
| Beyma 10WRS300 | 41 +3 | 0.276 +0.04 | 66.5 +10.5 | 5.8 -1.2 | 95.1 +0.9 | usable | 300 W vs 450 W: lower power handling · Xmax 5.8 mm < 7 mm: lower excursion-limited SPL | + |
| Volt BM2500.4 | 32 -6 | 0.213 -0.02 | 73 +17 | 6.6 -0.4 | 93.3 -0.9 | usable | 200 W vs 450 W: lower power handling · Xmax 6.6 mm < 7 mm: lower excursion-limited SPL | + |
| Eminence Kappa Pro-10LF | 39 +1 | 0.28 +0.05 | 72.97 +16.97 | 7.2 +0.2 | 91.6 -2.6 | usable | + |
Comparer les 3 plus proches avec le 10LW30/N →
Classé par similarité de paramètres uniquement (Qts, Fs, Vas, Xmax, sensibilité). Même taille nominale requise. Une indication, pas une simulation, modélisez l'échange avant de couper ou d'acheter.
Utilisé dans les caissons (0)
No enclosure in the catalog uses this driver yet.