Beyma 10LW30
Paramètres Thiele-Small
| Taille nominale | 10" |
|---|---|
| Impédance | 8 Ω |
| Fs | 42 Hz |
| Qts | 0.293 |
| Qes | 0.3 |
| Qms | 11.97 |
| Vas | 55 L |
| Sd | 360 cm² |
| Xmax | 7 mm |
| Re | 6 Ω |
| Bl | 15.8 T·m |
| Mms | 47.4 g |
| Pe | 450 W |
| Sensibilité | 94.6 dB |
Indication d'alignement
| EBP | 140 · ported |
|---|---|
| Sealed Vb (Qtc ≈ 0.71) | ≈ 11.4 L |
EBP > 100 : favorise un alignement bass-reflex.
Rules of thumb from T/S parameters only. Verify against a real simulation before cutting wood.
Candidats de substitution
| HP | Fs (Hz) | Qts | Vas (L) | Xmax (mm) | Sens (dB) | Adéquation | Notes | Comparer |
|---|---|---|---|---|---|---|---|---|
| Beyma 10"G40 | 45 +3 | 0.3 +0.01 | 49 -6 | 7 = | 95 +0.4 | close | + | |
| Faital PRO 10PR320 | 48 +6 | 0.29 = | 52.7 -2.3 | 7.37 +0.37 | 96 +1.4 | close | 300 W vs 450 W: lower power handling | + |
| Beyma 10G40 v2016 | 45 +3 | 0.306 +0.01 | 49 -6 | 6.6 -0.4 | 94.5 -0.1 | close | Xmax 6.6 mm < 7 mm: lower excursion-limited SPL | + |
| Sica 10 S 3 CP | 42 = | 0.3 +0.01 | 42.8 -12.2 | 7 = | 94 -0.6 | close | + | |
| Eminence KAPPALITE 3010LF-4 vp | 43.1 +1.1 | 0.281 -0.01 | 49.3 -5.7 | 8.4 +1.4 | 96.5 +1.9 | close | 4 Ω vs 8 Ω: amp load changes | + |
| SICA 10 S 3 CP 4 Ohms | 44 +2 | 0.281 -0.01 | 51.3 -3.7 | 7 = | 97.7 +3.1 | close | 4 Ω vs 8 Ω: amp load changes | + |
| Eminence KAPPALITE 3010 LF | 38.7 -3.3 | 0.273 -0.02 | 62.4 +7.4 | 8.5 +1.5 | 93.5 -1.1 | close | + | |
| Beyma 10WR300 | 47 +5 | 0.287 -0.01 | 50.5 -4.5 | 5.8 -1.2 | 95.5 +0.9 | close | 300 W vs 450 W: lower power handling · Xmax 5.8 mm < 7 mm: lower excursion-limited SPL | + |
| Eminence KAPPALITE 3010LF-4 | 40 -2 | 0.251 -0.04 | 53.5 -1.5 | 8.1 +1.1 | 96.4 +1.8 | close | 4 Ω vs 8 Ω: amp load changes | + |
| Sica 10 S 3 PL | 43 +1 | 0.27 -0.02 | 39.9 -15.1 | 7 = | 94.5 -0.1 | close | + |
Comparer les 3 plus proches avec le 10LW30 →
Classé par similarité de paramètres uniquement (Qts, Fs, Vas, Xmax, sensibilité). Même taille nominale requise. Une indication, pas une simulation, modélisez l'échange avant de couper ou d'acheter.
Utilisé dans les caissons (0)
No enclosure in the catalog uses this driver yet.