Beyma 10CX25
Paramètres Thiele-Small
| Taille nominale | 10" |
|---|---|
| Impédance | 8 Ω |
| Fs | 53 Hz |
| Qts | 0.366 |
| Qes | 0.38 |
| Qms | 10 |
| Vas | 66 L |
| Sd | 380 cm² |
| Xmax | 5 mm |
| Re | 6.3 Ω |
| Bl | 12.4 T·m |
| Mms | 27.7 g |
| Pe | 250 W |
| Sensibilité | 97.1 dB |
Indication d'alignement
| EBP | 139 · ported |
|---|---|
| Sealed Vb (Qtc ≈ 0.71) | ≈ 24.2 L |
EBP > 100 : favorise un alignement bass-reflex.
Rules of thumb from T/S parameters only. Verify against a real simulation before cutting wood.
Candidats de substitution
| HP | Fs (Hz) | Qts | Vas (L) | Xmax (mm) | Sens (dB) | Adéquation | Notes | Comparer |
|---|---|---|---|---|---|---|---|---|
| Eminence BETA 10CX | 49 -4 | 0.397 +0.03 | 64.2 -1.8 | 5 = | 96 -1.1 | close | + | |
| Eminence BETA 10CX-8 | 48 -5 | 0.397 +0.03 | 64.2 -1.8 | 5 = | 95.8 -1.3 | close | + | |
| Eminence BETA 10CX | 49 -4 | 0.38 +0.01 | 61.1 -4.9 | 5 = | 94.3 -2.8 | close | + | |
| Beyma 10CX300/FE | 48 -5 | 0.38 +0.01 | 62.7 -3.3 | 6.75 +1.75 | 94.1 -3 | close | + | |
| SICA 10 C 2 CP v2017 | 50 -3 | 0.308 -0.06 | 63.2 -2.8 | 4.5 -0.5 | 96.9 -0.2 | close | 150 W vs 250 W: lower power handling · Xmax 4.5 mm < 5 mm: lower excursion-limited SPL | + |
| Eminence DELTALITE II 2510 (prodance) | 53.4 +0.4 | 0.384 +0.02 | 50.9 -15.1 | 4.2 -0.8 | 96.9 -0.2 | close | Xmax 4.2 mm < 5 mm: lower excursion-limited SPL | + |
| B&C 10 HPL 51 | 55 +2 | 0.367 = | 50 -16 | 4 -1 | 97.1 = | close | 150 W vs 250 W: lower power handling · Xmax 4 mm < 5 mm: lower excursion-limited SPL | + |
| SICA 10 C 2 CP | 54 +1 | 0.339 -0.03 | 53.6 -12.4 | 4 -1 | 96.6 -0.5 | usable | 150 W vs 250 W: lower power handling · Xmax 4 mm < 5 mm: lower excursion-limited SPL | + |
| Eminence DELTALITE II 2510-4 | 55 +2 | 0.381 +0.02 | 54.5 -11.5 | 4.2 -0.8 | 99.2 +2.1 | usable | 4 Ω vs 8 Ω: amp load changes · Xmax 4.2 mm < 5 mm: lower excursion-limited SPL | + |
| Volt BM251.3 PA | 55 +2 | 0.346 -0.02 | 44 -22 | 4.8 -0.2 | 96.8 -0.3 | usable | Xmax 4.8 mm < 5 mm: lower excursion-limited SPL | + |
Comparer les 3 plus proches avec le 10CX25 →
Classé par similarité de paramètres uniquement (Qts, Fs, Vas, Xmax, sensibilité). Même taille nominale requise. Une indication, pas une simulation, modélisez l'échange avant de couper ou d'acheter.
Utilisé dans les caissons (0)
No enclosure in the catalog uses this driver yet.