B&C 18PS100
Paramètres Thiele-Small
| Taille nominale | 18" |
|---|---|
| Impédance | 4 Ω |
| Fs | 30 Hz |
| Qts | 0.4 |
| Qes | 0.42 |
| Qms | 9.1 |
| Vas | 251 L |
| Sd | 1210 cm² |
| Xmax | 7 mm |
| Re | 3.8 Ω |
| Bl | 20 T·m |
| Mms | 239 g |
| Pe | 700 W |
| Sensibilité | 94 dB |
Indication d'alignement
| EBP | 71 · flexible |
|---|---|
| Sealed Vb (Qtc ≈ 0.71) | ≈ 118.1 L |
EBP 50-100 : fonctionne en clos ou en bass-reflex.
Rules of thumb from T/S parameters only. Verify against a real simulation before cutting wood.
Candidats de substitution
| HP | Fs (Hz) | Qts | Vas (L) | Xmax (mm) | Sens (dB) | Adéquation | Notes | Comparer |
|---|---|---|---|---|---|---|---|---|
| B&C 18PS100 | 30 = | 0.39 -0.01 | 245 -6 | 8 +1 | 95.5 +1.5 | close | 8 Ω vs 4 Ω: amp load changes | + |
| P.Audio E-18ELF | 30 = | 0.44 +0.04 | 263.57 +12.57 | 7.5 +0.5 | 93.6 -0.4 | close | 8 Ω vs 4 Ω: amp load changes | + |
| B&C 18 PS 100 8 Ohms | 30 = | 0.376 -0.02 | 245 -6 | 8 +1 | 95.8 +1.8 | close | 8 Ω vs 4 Ω: amp load changes | + |
| BMS 18N830V2 | 31 +1 | 0.37 -0.03 | 262 +11 | 8 +1 | 94.9 +0.9 | close | 6 Ω vs 4 Ω: amp load changes · 550 W vs 700 W: lower power handling | + |
| B&C 18 PS 100 4 Ohms | 30 = | 0.394 -0.01 | 251.8 +0.8 | 8 +1 | 98.4 +4.4 | close | + | |
| Sica 18 PFS 4 | 28.7 -1.3 | 0.37 -0.03 | 245.9 -5.1 | 9.5 +2.5 | 95.1 +1.1 | close | 8 Ω vs 4 Ω: amp load changes | + |
| BMS 18N830vv2 | 31 +1 | 0.37 -0.03 | 262 +11 | 8 +1 | 96 +2 | close | 8 Ω vs 4 Ω: amp load changes | + |
| DAS Audio 18LX vp | 32.3 +2.3 | 0.4 = | 260.7 +9.7 | 6 -1 | 95.8 +1.8 | close | 8 Ω vs 4 Ω: amp load changes · Xmax 6 mm < 7 mm: lower excursion-limited SPL | + |
| Fane SOVEREIGN PRO 18-800 P | 33 +3 | 0.386 -0.01 | 258 +7 | 7.5 +0.5 | 96.4 +2.4 | close | 8 Ω vs 4 Ω: amp load changes | + |
| Peavey LOW RIDER 18 | 28.9 -1.1 | 0.429 +0.03 | 288 +37 | 9.6 +2.6 | 93.7 -0.3 | close | 8 Ω vs 4 Ω: amp load changes | + |
Comparer les 3 plus proches avec le 18PS100 →
Classé par similarité de paramètres uniquement (Qts, Fs, Vas, Xmax, sensibilité). Même taille nominale requise. Une indication, pas une simulation, modélisez l'échange avant de couper ou d'acheter.
Utilisé dans les caissons (0)
No enclosure in the catalog uses this driver yet.