B&C 18 SW 100
Paramètres Thiele-Small
| Taille nominale | 18" |
|---|---|
| Impédance | 8 Ω |
| Fs | 35 Hz |
| Qts | 0.375 |
| Qes | 0.4 |
| Qms | 5.9 |
| Vas | 180 L |
| Sd | 1210 cm² |
| Xmax | 9.7 mm |
| Re | 5 Ω |
| Bl | 25.5 T·m |
| Mms | 235.8 g |
| Pe | 1500 W |
| Sensibilité | 96.9 dB |
Indication d'alignement
| EBP | 88 · flexible |
|---|---|
| Sealed Vb (Qtc ≈ 0.71) | ≈ 70.4 L |
EBP 50-100 : fonctionne en clos ou en bass-reflex.
Rules of thumb from T/S parameters only. Verify against a real simulation before cutting wood.
Candidats de substitution
| HP | Fs (Hz) | Qts | Vas (L) | Xmax (mm) | Sens (dB) | Adéquation | Notes | Comparer |
|---|---|---|---|---|---|---|---|---|
| B&C 18SW100 | 35 = | 0.38 +0.01 | 180 = | 12.5 +2.8 | 97 +0.1 | close | + | |
| B&C 18NBX100 | 35 = | 0.37 -0.01 | 192 +12 | 10 +0.3 | 96 -0.9 | close | 4 Ω vs 8 Ω: amp load changes | + |
| B&C 18NBX100 | 35 = | 0.38 +0.01 | 198 +18 | 10 +0.3 | 96.5 -0.4 | close | + | |
| Beyma 18LEX1600Fe | 34 -1 | 0.38 +0.01 | 188 +8 | 13 +3.3 | 97 +0.1 | close | + | |
| B&C 18TBW100 | 35 = | 0.39 +0.02 | 175 -5 | 12 +2.3 | 96 -0.9 | close | + | |
| Celestion POWER PRO X18 | 34.8 -0.2 | 0.379 = | 188.9 +8.9 | 8.6 -1.1 | 96.6 -0.3 | close | Xmax 8.6 mm < 9.7 mm: lower excursion-limited SPL | + |
| PD PD 185N01 | 35.6 +0.6 | 0.383 +0.01 | 174.5 -5.5 | 8.4 -1.3 | 97.1 +0.2 | close | 1000 W vs 1500 W: lower power handling · Xmax 8.4 mm < 9.7 mm: lower excursion-limited SPL | + |
| Precision Devices PD 185N01 | 35.6 +0.6 | 0.383 +0.01 | 174.5 -5.5 | 8.4 -1.3 | 97.1 +0.2 | close | 1000 W vs 1500 W: lower power handling · Xmax 8.4 mm < 9.7 mm: lower excursion-limited SPL | + |
| Beyma 18LEX1600/ND-8 | 35 = | 0.39 +0.02 | 205 +25 | 10.4 +0.7 | 96.8 -0.1 | close | + | |
| Fane 18XLS | 36 +1 | 0.407 +0.03 | 187 +7 | 9.3 -0.4 | 97 +0.1 | close | Xmax 9.3 mm < 9.7 mm: lower excursion-limited SPL | + |
Comparer les 3 plus proches avec le 18 SW 100 →
Classé par similarité de paramètres uniquement (Qts, Fs, Vas, Xmax, sensibilité). Même taille nominale requise. Une indication, pas une simulation, modélisez l'échange avant de couper ou d'acheter.
Utilisé dans les caissons (0)
No enclosure in the catalog uses this driver yet.