B&C 15 PS 100 (prodance)
Paramètres Thiele-Small
| Taille nominale | 15" |
|---|---|
| Impédance | 8 Ω |
| Fs | 34.8 Hz |
| Qts | 0.339 |
| Qes | 0.36 |
| Qms | 5.95 |
| Vas | 148.7 L |
| Sd | 855 cm² |
| Xmax | 8 mm |
| Re | 5.25 Ω |
| Bl | 21.4 T·m |
| Mms | 143.9 g |
| Pe | 700 W |
| Sensibilité | 96.2 dB |
Indication d'alignement
| EBP | 97 · flexible |
|---|---|
| Sealed Vb (Qtc ≈ 0.71) | ≈ 44.4 L |
EBP 50-100 : fonctionne en clos ou en bass-reflex.
Rules of thumb from T/S parameters only. Verify against a real simulation before cutting wood.
Candidats de substitution
| HP | Fs (Hz) | Qts | Vas (L) | Xmax (mm) | Sens (dB) | Adéquation | Notes | Comparer |
|---|---|---|---|---|---|---|---|---|
| Volt RV3863 v2014 | 35 +0.2 | 0.343 = | 150 +1.3 | 6.7 -1.3 | 95.8 -0.4 | close | 400 W vs 700 W: lower power handling · Xmax 6.7 mm < 8 mm: lower excursion-limited SPL | + |
| RCF L 15P200AK-II | 38 +3.2 | 0.336 = | 139 -9.7 | 8.3 +0.3 | 96.3 +0.1 | close | + | |
| Faital PRO 15FH520 | 38 +3.2 | 0.34 = | 153.2 +4.5 | 9.15 +1.15 | 97 +0.8 | close | 4 Ω vs 8 Ω: amp load changes | + |
| 18 Sound 15NLW9500 | 35 +0.2 | 0.32 -0.02 | 163 +14.3 | 9 +1 | 96 -0.2 | close | + | |
| RCF L 15P200AK | 38 +3.2 | 0.351 +0.01 | 139 -9.7 | 8.2 +0.2 | 96.4 +0.2 | close | + | |
| B&C 15 PS 100 | 33 -1.8 | 0.309 -0.03 | 150.1 +1.4 | 7.8 -0.2 | 95.9 -0.3 | close | Xmax 7.8 mm < 8 mm: lower excursion-limited SPL | + |
| Beyma 15P1000 | 35 +0.2 | 0.293 -0.05 | 146 -2.7 | 8.7 +0.7 | 96.3 +0.1 | close | + | |
| PHL Audio 5021 | 33.7 -1.1 | 0.345 +0.01 | 147 -1.7 | 6.6 -1.4 | 95.3 -0.9 | close | 500 W vs 700 W: lower power handling · Xmax 6.6 mm < 8 mm: lower excursion-limited SPL | + |
| RCF L 15P200AK-I | 38 +3.2 | 0.36 +0.02 | 139 -9.7 | 8.5 +0.5 | 96.3 +0.1 | close | + | |
| Peavey LOW RIDER 15 | 33.9 -0.9 | 0.352 +0.01 | 155.1 +6.4 | 9.6 +1.6 | 94 -2.2 | close | + |
Comparer les 3 plus proches avec le 15 PS 100 (prodance) →
Classé par similarité de paramètres uniquement (Qts, Fs, Vas, Xmax, sensibilité). Même taille nominale requise. Une indication, pas une simulation, modélisez l'échange avant de couper ou d'acheter.
Utilisé dans les caissons (0)
No enclosure in the catalog uses this driver yet.