B&C 15 NDL 88
Paramètres Thiele-Small
| Taille nominale | 15" |
|---|---|
| Impédance | 8 Ω |
| Fs | 45 Hz |
| Qts | 0.34 |
| Qes | 0.36 |
| Qms | 6.1 |
| Vas | 126 L |
| Sd | 855 cm² |
| Xmax | 6.6 mm |
| Re | 5 Ω |
| Bl | 20 T·m |
| Mms | 101.7 g |
| Pe | 700 W |
| Sensibilité | 99.1 dB |
Indication d'alignement
| EBP | 125 · ported |
|---|---|
| Sealed Vb (Qtc ≈ 0.71) | ≈ 37.9 L |
EBP > 100 : favorise un alignement bass-reflex.
Rules of thumb from T/S parameters only. Verify against a real simulation before cutting wood.
Candidats de substitution
| HP | Fs (Hz) | Qts | Vas (L) | Xmax (mm) | Sens (dB) | Adéquation | Notes | Comparer |
|---|---|---|---|---|---|---|---|---|
| B&C 15NDL88 | 45 = | 0.34 = | 126 = | 8 +1.4 | 99 -0.1 | close | + | |
| Beyma 15MCB700 | 44 -1 | 0.34 = | 148 +22 | 7 +0.4 | 99 -0.1 | close | + | |
| MC Kenzie C15.500BS | 45 = | 0.35 +0.01 | 145 +19 | 6.5 -0.1 | 98.8 -0.3 | close | 500 W vs 700 W: lower power handling · Xmax 6.5 mm < 6.6 mm: lower excursion-limited SPL | + |
| Eminence KAPPA PRO 15 LF v1 | 46 +1 | 0.372 +0.03 | 127.5 +1.5 | 6.4 -0.2 | 98.6 -0.5 | close | Xmax 6.4 mm < 6.6 mm: lower excursion-limited SPL | + |
| Oberton 15MB35 | 47.7 +2.7 | 0.336 = | 115.1 -10.9 | 6.75 +0.15 | 100 +0.9 | close | + | |
| Sica 15 PF 3 | 45 = | 0.31 -0.03 | 117.6 -8.4 | 8 +1.4 | 99.1 = | close | + | |
| B&C 15CL76 | 42 -3 | 0.33 -0.01 | 135 +9 | 7 +0.4 | 98.5 -0.6 | close | 400 W vs 700 W: lower power handling | + |
| 18 Sound 15W1301 | 48 +3 | 0.355 +0.01 | 123 -3 | 6 -0.6 | 99.3 +0.2 | close | Xmax 6 mm < 6.6 mm: lower excursion-limited SPL | + |
| Beyma 15G450 | 45 = | 0.32 -0.02 | 115 -11 | 6.2 -0.4 | 98.5 -0.6 | close | Xmax 6.2 mm < 6.6 mm: lower excursion-limited SPL | + |
| Beyma 15G450/N | 45 = | 0.32 -0.02 | 115 -11 | 6.2 -0.4 | 98.5 -0.6 | close | Xmax 6.2 mm < 6.6 mm: lower excursion-limited SPL | + |
Comparer les 3 plus proches avec le 15 NDL 88 →
Classé par similarité de paramètres uniquement (Qts, Fs, Vas, Xmax, sensibilité). Même taille nominale requise. Une indication, pas une simulation, modélisez l'échange avant de couper ou d'acheter.
Utilisé dans les caissons (0)
No enclosure in the catalog uses this driver yet.