B&C 15 CXN 88
Paramètres Thiele-Small
| Taille nominale | 15" |
|---|---|
| Impédance | 8 Ω |
| Fs | 40 Hz |
| Qts | 0.254 |
| Qes | 0.26 |
| Qms | 10.3 |
| Vas | 178 L |
| Sd | 855 cm² |
| Xmax | 6 mm |
| Re | 5 Ω |
| Bl | 21 T·m |
| Mms | 91.1 g |
| Pe | 500 W |
| Sensibilité | 100.4 dB |
Indication d'alignement
| EBP | 154 · ported |
|---|---|
| Sealed Vb (Qtc ≈ 0.71) | ≈ 26.4 L |
EBP > 100 : favorise un alignement bass-reflex.
Rules of thumb from T/S parameters only. Verify against a real simulation before cutting wood.
Candidats de substitution
| HP | Fs (Hz) | Qts | Vas (L) | Xmax (mm) | Sens (dB) | Adéquation | Notes | Comparer |
|---|---|---|---|---|---|---|---|---|
| PHL Audio 5050 | 38 -2 | 0.254 = | 180 +2 | 5.9 -0.1 | 99.2 -1.2 | close | Xmax 5.9 mm < 6 mm: lower excursion-limited SPL | + |
| PHL Audio 5140 | 38 -2 | 0.245 -0.01 | 180 +2 | 5.7 -0.3 | 100.6 +0.2 | close | Xmax 5.7 mm < 6 mm: lower excursion-limited SPL | + |
| PHL Audio 5030 | 40 = | 0.236 -0.02 | 180 +2 | 5.4 -0.6 | 100.2 -0.2 | close | Xmax 5.4 mm < 6 mm: lower excursion-limited SPL | + |
| Sica 15 K 3 PL | 40 = | 0.27 +0.02 | 166.1 -11.9 | 6.5 +0.5 | 99.7 -0.7 | close | + | |
| PD PD 158 | 39.9 -0.1 | 0.241 -0.01 | 161.9 -16.1 | 5.9 -0.1 | 99.4 -1 | close | Xmax 5.9 mm < 6 mm: lower excursion-limited SPL | + |
| Precision Devices PD 158 | 39.9 -0.1 | 0.241 -0.01 | 161.9 -16.1 | 5.9 -0.1 | 99.4 -1 | close | Xmax 5.9 mm < 6 mm: lower excursion-limited SPL | + |
| PHL Audio 5200 | 38 -2 | 0.272 +0.02 | 180 +2 | 6 = | 101.6 +1.2 | close | 4 Ω vs 8 Ω: amp load changes | + |
| 18 Sound 15NLW9300 v2015 | 39 -1 | 0.263 +0.01 | 170 -8 | 7.2 +1.2 | 98.9 -1.5 | close | + | |
| PD PD 153 C01 | 39 -1 | 0.265 +0.01 | 195 +17 | 5.5 -0.5 | 100.2 -0.2 | close | Xmax 5.5 mm < 6 mm: lower excursion-limited SPL | + |
| Precision Devices PD 153 C01 | 39 -1 | 0.265 +0.01 | 195 +17 | 5.5 -0.5 | 100.2 -0.2 | close | Xmax 5.5 mm < 6 mm: lower excursion-limited SPL | + |
Comparer les 3 plus proches avec le 15 CXN 88 →
Classé par similarité de paramètres uniquement (Qts, Fs, Vas, Xmax, sensibilité). Même taille nominale requise. Une indication, pas une simulation, modélisez l'échange avant de couper ou d'acheter.
Utilisé dans les caissons (0)
No enclosure in the catalog uses this driver yet.