B&C 15 BG 100
Paramètres Thiele-Small
| Taille nominale | 15" |
|---|---|
| Impédance | 8 Ω |
| Fs | 36 Hz |
| Qts | 0.446 |
| Qes | 0.49 |
| Qms | 5 |
| Vas | 83 L |
| Sd | 855 cm² |
| Xmax | 8 mm |
| Re | 5.1 Ω |
| Bl | 23.8 T·m |
| Mms | 241.3 g |
| Pe | 1000 W |
| Sensibilité | 92.9 dB |
Indication d'alignement
| EBP | 73 · flexible |
|---|---|
| Sealed Vb (Qtc ≈ 0.71) | ≈ 54.8 L |
EBP 50-100 : fonctionne en clos ou en bass-reflex.
Rules of thumb from T/S parameters only. Verify against a real simulation before cutting wood.
Candidats de substitution
| HP | Fs (Hz) | Qts | Vas (L) | Xmax (mm) | Sens (dB) | Adéquation | Notes | Comparer |
|---|---|---|---|---|---|---|---|---|
| B&C 15BG100 | 36 = | 0.44 -0.01 | 83 = | 10.5 +2.5 | 94.5 +1.6 | close | + | |
| Ciare 15.00SW | 38.2 +2.2 | 0.415 -0.03 | 77 -6 | 8.4 +0.4 | 92.6 -0.3 | close | + | |
| JBL 15WT3000 | 41 +5 | 0.44 -0.01 | 76.3 -6.7 | 10.6 +2.6 | 92.5 -0.4 | close | 4 Ω vs 8 Ω: amp load changes | + |
| Ciare 15.00 SW | 38.2 +2.2 | 0.41 -0.04 | 77 -6 | 11.5 +3.5 | 91.7 -1.2 | close | + | |
| Gladen SQX15 | 35.5 -0.5 | 0.513 +0.07 | 80.7 -2.3 | 7 -1 | 94.3 +1.4 | close | 4 Ω vs 8 Ω: amp load changes · 700 W vs 1000 W: lower power handling · Xmax 7 mm < 8 mm: lower excursion-limited SPL | + |
| FI Audio Q15 DUAL 2 | 32.1 -3.9 | 0.419 -0.03 | 75.6 -7.4 | 11.3 +3.3 | 94.1 +1.2 | close | 4 Ω vs 8 Ω: amp load changes | + |
| Dayton Audio PA385S-8 v2018 | 37.7 +1.7 | 0.373 -0.07 | 80.4 -2.6 | 7.2 -0.8 | 93.6 +0.7 | close | Xmax 7.2 mm < 8 mm: lower excursion-limited SPL | + |
| B&C 15PS100 | 39 +3 | 0.43 -0.02 | 103 +20 | 8 = | 95 +2.1 | close | 700 W vs 1000 W: lower power handling | + |
| Faital PRO 15XL1200 | 40 +4 | 0.4 -0.05 | 86.9 +3.9 | 12.45 +4.45 | 95 +2.1 | usable | + | |
| B&C 15 PS 100 v2016 | 39 +3 | 0.436 -0.01 | 103 +20 | 7.2 -0.8 | 95 +2.1 | usable | 700 W vs 1000 W: lower power handling · Xmax 7.2 mm < 8 mm: lower excursion-limited SPL | + |
Comparer les 3 plus proches avec le 15 BG 100 →
Classé par similarité de paramètres uniquement (Qts, Fs, Vas, Xmax, sensibilité). Même taille nominale requise. Une indication, pas une simulation, modélisez l'échange avant de couper ou d'acheter.
Utilisé dans les caissons (0)
No enclosure in the catalog uses this driver yet.