B&C 10 PS 26
Paramètres Thiele-Small
| Taille nominale | 10" |
|---|---|
| Impédance | 8 Ω |
| Fs | 54 Hz |
| Qts | 0.296 |
| Qes | 0.33 |
| Qms | 2.9 |
| Vas | 38 L |
| Sd | 320 cm² |
| Xmax | 5.5 mm |
| Re | 5.8 Ω |
| Bl | 14 T·m |
| Mms | 32.8 g |
| Pe | 350 W |
| Sensibilité | 96 dB |
Indication d'alignement
| EBP | 164 · ported |
|---|---|
| Sealed Vb (Qtc ≈ 0.71) | ≈ 8.1 L |
EBP > 100 : favorise un alignement bass-reflex.
Rules of thumb from T/S parameters only. Verify against a real simulation before cutting wood.
Candidats de substitution
| HP | Fs (Hz) | Qts | Vas (L) | Xmax (mm) | Sens (dB) | Adéquation | Notes | Comparer |
|---|---|---|---|---|---|---|---|---|
| B&C 10PS26 | 54 = | 0.29 -0.01 | 38 = | 5.5 = | 96 = | close | + | |
| Sica 10 N 3 PL | 51 -3 | 0.29 -0.01 | 40.5 +2.5 | 5.5 = | 96.1 +0.1 | close | + | |
| Sica 10 Fe 3 CP | 52 -2 | 0.31 +0.01 | 38.6 +0.6 | 5 -0.5 | 95.9 -0.1 | close | Xmax 5 mm < 5.5 mm: lower excursion-limited SPL | + |
| B&C 10 PS 26 (prodance) | 53.4 -0.6 | 0.267 -0.03 | 39.5 +1.5 | 5.4 -0.1 | 96.8 +0.8 | close | Xmax 5.4 mm < 5.5 mm: lower excursion-limited SPL | + |
| Faital PRO 10PR310 | 55 +1 | 0.31 +0.01 | 40.3 +2.3 | 4.92 -0.58 | 97 +1 | close | 4 Ω vs 8 Ω: amp load changes · Xmax 4.92 mm < 5.5 mm: lower excursion-limited SPL | + |
| SICA 10 FE 3 CP v2017 | 52 -2 | 0.307 +0.01 | 38.6 +0.6 | 4.2 -1.3 | 95.8 -0.2 | close | Xmax 4.2 mm < 5.5 mm: lower excursion-limited SPL | + |
| Monacor SP-10A/302PA | 55 +1 | 0.298 = | 40 +2 | 4 -1.5 | 96.3 +0.3 | close | Xmax 4 mm < 5.5 mm: lower excursion-limited SPL | + |
| 18 Sound 10W500 | 53 -1 | 0.29 -0.01 | 45.2 +7.2 | 5.5 = | 98 +2 | close | + | |
| Beyma 10G40 | 55 +1 | 0.314 +0.02 | 33 -5 | 5 -0.5 | 95.4 -0.6 | close | Xmax 5 mm < 5.5 mm: lower excursion-limited SPL | + |
| SB Audience BIANCO-10MW200 | 58 +4 | 0.336 +0.04 | 39.3 +1.3 | 5.2 -0.3 | 96.2 +0.2 | close | Xmax 5.2 mm < 5.5 mm: lower excursion-limited SPL | + |
Comparer les 3 plus proches avec le 10 PS 26 →
Classé par similarité de paramètres uniquement (Qts, Fs, Vas, Xmax, sensibilité). Même taille nominale requise. Une indication, pas une simulation, modélisez l'échange avant de couper ou d'acheter.
Utilisé dans les caissons (0)
No enclosure in the catalog uses this driver yet.