Axon 12K01
Paramètres Thiele-Small
| Taille nominale | 12" |
|---|---|
| Impédance | 4 Ω |
| Fs | 25 Hz |
| Qts | 0.289 |
| Qes | 0.34 |
| Qms | 1.94 |
| Vas | 191.8 L |
| Sd | 499 cm² |
| Xmax | 6.7 mm |
| Re | 3.2 Ω |
| Bl | 10.4 T·m |
| Mms | 73.8 g |
| Pe | 125 W |
| Sensibilité | 95.4 dB |
Indication d'alignement
| EBP | 74 · flexible |
|---|---|
| Sealed Vb (Qtc ≈ 0.71) | ≈ 38.5 L |
EBP 50-100 : fonctionne en clos ou en bass-reflex.
Rules of thumb from T/S parameters only. Verify against a real simulation before cutting wood.
Candidats de substitution
| HP | Fs (Hz) | Qts | Vas (L) | Xmax (mm) | Sens (dB) | Adéquation | Notes | Comparer |
|---|---|---|---|---|---|---|---|---|
| Great Plains Audio 3124 GPA | 26 +1 | 0.288 = | 186.9 -4.9 | 6.4 -0.3 | 93.1 -2.3 | close | 8 Ω vs 4 Ω: amp load changes · Xmax 6.4 mm < 6.7 mm: lower excursion-limited SPL | + |
| Altec 3124 | 26 +1 | 0.288 = | 186.9 -4.9 | 6.4 -0.3 | 92.9 -2.5 | close | 8 Ω vs 4 Ω: amp load changes · Xmax 6.4 mm < 6.7 mm: lower excursion-limited SPL | + |
| Jensen RS12045SW | 25 = | 0.3 +0.01 | 220 +28.2 | 11 +4.3 | 95.6 +0.2 | close | + | |
| Scan-Speak 32W/4878T01 | 23 -2 | 0.286 = | 170 -21.8 | 7 +0.3 | 94.5 -0.9 | close | + | |
| TVM ARN 312-00/4 | 22 -3 | 0.289 = | 206 +14.2 | 6.4 -0.3 | 93.8 -1.6 | close | Xmax 6.4 mm < 6.7 mm: lower excursion-limited SPL | + |
| Visaton WS33NG | 30 +5 | 0.308 +0.02 | 190 -1.8 | 8 +1.3 | 94.5 -0.9 | close | 8 Ω vs 4 Ω: amp load changes | + |
| Eton 12-680/A8/62 HEX SYMPHONIE II | 26 +1 | 0.296 +0.01 | 173 -18.8 | 6 -0.7 | 92.8 -2.6 | close | 8 Ω vs 4 Ω: amp load changes · Xmax 6 mm < 6.7 mm: lower excursion-limited SPL | + |
| Audiotechnology FLEXUNIT 12B772510 | 25 = | 0.299 +0.01 | 250 +58.2 | 8.6 +1.9 | 94.3 -1.1 | close | 8 Ω vs 4 Ω: amp load changes | + |
| STX W.STX.12.2.500.4.F.S.MC | 25 = | 0.31 +0.02 | 151 -40.8 | 7.5 +0.8 | 94.3 -1.1 | close | + | |
| Visaton TIW300 | 25 = | 0.282 -0.01 | 160 -31.8 | 9.7 +3 | 92.9 -2.5 | close | 8 Ω vs 4 Ω: amp load changes | + |
Comparer les 3 plus proches avec le 12K01 →
Classé par similarité de paramètres uniquement (Qts, Fs, Vas, Xmax, sensibilité). Même taille nominale requise. Une indication, pas une simulation, modélisez l'échange avant de couper ou d'acheter.
Utilisé dans les caissons (0)
No enclosure in the catalog uses this driver yet.