Aurum Cantus AC250F1
Paramètres Thiele-Small
| Taille nominale | 10" |
|---|---|
| Impédance | 8 Ω |
| Fs | 20 Hz |
| Qts | 0.287 |
| Qes | 0.32 |
| Qms | 2.75 |
| Vas | 224 L |
| Sd | 346 cm² |
| Xmax | 8 mm |
| Re | 7 Ω |
| Bl | 11.4 T·m |
| Mms | 47.4 g |
| Pe | 150 W |
| Sensibilité | 90 dB |
Indication d'alignement
| EBP | 63 · flexible |
|---|---|
| Sealed Vb (Qtc ≈ 0.71) | ≈ 44.2 L |
EBP 50-100 : fonctionne en clos ou en bass-reflex.
Rules of thumb from T/S parameters only. Verify against a real simulation before cutting wood.
Candidats de substitution
| HP | Fs (Hz) | Qts | Vas (L) | Xmax (mm) | Sens (dB) | Adéquation | Notes | Comparer |
|---|---|---|---|---|---|---|---|---|
| Scan-Speak 26W/8861T00 | 19 -1 | 0.31 +0.02 | 234 +10 | 9 +1 | 90 = | close | 80 W vs 150 W: lower power handling | + |
| Scan-Speak 26W/4867T00 | 18 -2 | 0.294 +0.01 | 223 -1 | 9 +1 | 91.6 +1.6 | close | 4 Ω vs 8 Ω: amp load changes | + |
| Scan-Speak 26W/8867T00 | 19 -1 | 0.29 = | 179 -45 | 9 +1 | 89.4 -0.6 | close | + | |
| Scan-Speak 26W8867T00 | 19 -1 | 0.29 = | 176 -48 | 9 +1 | 89.3 -0.7 | close | + | |
| Accuton S280-6-282 | 20 = | 0.263 -0.02 | 226 +2 | 6 -2 | 90.9 +0.9 | close | Xmax 6 mm < 8 mm: lower excursion-limited SPL | + |
| Visaton WSP26S | 19 -1 | 0.34 +0.05 | 230 +6 | 11 +3 | 90.2 +0.2 | close | 110 W vs 150 W: lower power handling | + |
| Aurum Cantus AC250/75C2C | 23 +3 | 0.275 -0.01 | 193 -31 | 8 = | 91.2 +1.2 | close | + | |
| Scan-Speak 25W/8565-01 | 19 -1 | 0.338 +0.05 | 229 +5 | 6.5 -1.5 | 90 = | close | 100 W vs 150 W: lower power handling · Xmax 6.5 mm < 8 mm: lower excursion-limited SPL | + |
| Monacor SPH-250CTC vp CARBON | 20 = | 0.247 -0.04 | 220 -4 | 7.5 -0.5 | 94 +4 | usable | 4 Ω vs 8 Ω: amp load changes · 100 W vs 150 W: lower power handling · Xmax 7.5 mm < 8 mm: lower excursion-limited SPL | + |
| Focal 10L 6411 | 22.4 +2.4 | 0.253 -0.03 | 210.4 -13.6 | 8 = | 93.5 +3.5 | usable | + |
Comparer les 3 plus proches avec le AC250F1 →
Classé par similarité de paramètres uniquement (Qts, Fs, Vas, Xmax, sensibilité). Même taille nominale requise. Une indication, pas une simulation, modélisez l'échange avant de couper ou d'acheter.
Utilisé dans les caissons (0)
No enclosure in the catalog uses this driver yet.