← tous les HP

Audiotechnology 10C772510KAP

10" · 8 Ω · 200 W · 92.1 dB · datasheet ↗

Paramètres Thiele-Small

Taille nominale10"
Impédance8 Ω
Fs25 Hz
Qts0.24
Qes0.25
Qms6
Vas110 L
Sd334 cm²
Xmax8.6 mm
Re5.4 Ω
Bl14 T·m
Mms57.6 g
Pe200 W
Sensibilité92.1 dB

Indication d'alignement

EBP100 · flexible
Sealed Vb (Qtc ≈ 0.71)≈ 14.3 L

EBP 50-100 : fonctionne en clos ou en bass-reflex.

Rules of thumb from T/S parameters only. Verify against a real simulation before cutting wood.

Candidats de substitution

HPFs (Hz)QtsVas (L)Xmax (mm)Sens (dB)AdéquationNotesComparer
Audiotechnology FLEXUNITS 10 C 77 25 10 KAP25 =0.24 =110 =8.6 =90.2 -1.9close+
Audiotechnology FLEXUNIT 10A77251025 =0.258 +0.02140 +308.6 =92.5 +0.4close+
Visaton GF 250 - série24 -10.272 +0.03134 +249.3 +0.791.1 -1close150 W vs 200 W: lower power handling+
Visaton GF 250 v2017 - 2x4 Ohms série24 -10.272 +0.03134 +249.3 +0.791.1 -1close150 W vs 200 W: lower power handling+
Axon 10K0125 =0.286 +0.05104.6 -5.47 -1.692.9 +0.8close4 Ω vs 8 Ω: amp load changes · 125 W vs 200 W: lower power handling · Xmax 7 mm < 8.6 mm: lower excursion-limited SPL+
Audiotechnology 10B773010KA24.4 -0.60.283 +0.04128 +189.8 +1.291 -1.1close150 W vs 200 W: lower power handling+
Vifa M26WR09-0427 +20.28 +0.04113 +36.5 -2.193 +0.9usableXmax 6.5 mm < 8.6 mm: lower excursion-limited SPL+
Visaton GF 25026 +10.289 +0.05110 =8.3 -0.396.9 +4.8usable2 Ω vs 8 Ω: amp load changes · 150 W vs 200 W: lower power handling · Xmax 8.3 mm < 8.6 mm: lower excursion-limited SPL+
Dayton Audio RS270P-4A22.9 -2.10.272 +0.03110.5 +0.56 -2.691 -1.1usable4 Ω vs 8 Ω: amp load changes · 100 W vs 200 W: lower power handling · Xmax 6 mm < 8.6 mm: lower excursion-limited SPL+
ATC SB75-234 LC26 +10.224 -0.02120 +105 -3.691.8 -0.3usable75 W vs 200 W: lower power handling · Xmax 5 mm < 8.6 mm: lower excursion-limited SPL+

Comparer les 3 plus proches avec le 10C772510KAP →

Classé par similarité de paramètres uniquement (Qts, Fs, Vas, Xmax, sensibilité). Même taille nominale requise. Une indication, pas une simulation, modélisez l'échange avant de couper ou d'acheter.

Utilisé dans les caissons (0)

No enclosure in the catalog uses this driver yet.