← tous les HP

Audio System HX12 SQ

12" · 4 Ω · 450 W · 86.1 dB · datasheet ↗

Paramètres Thiele-Small

Taille nominale12"
Impédance4 Ω
Fs28.2 Hz
Qts0.5
Qes0.57
Qms4.4
Vas68 L
Sd507 cm²
Xmax11.8 mm
Re3.1 Ω
Bl13.1 T·m
Mms150 g
Pe450 W
Sensibilité86.1 dB

Indication d'alignement

EBP49 · sealed
Sealed Vb (Qtc ≈ 0.71)≈ 68 L

EBP < 50 : favorise un alignement clos.

Rules of thumb from T/S parameters only. Verify against a real simulation before cutting wood.

Candidats de substitution

HPFs (Hz)QtsVas (L)Xmax (mm)Sens (dB)AdéquationNotesComparer
Infinity KAPPA 1200W26.5 -1.70.496 =64.47 -3.5312.75 +0.9585.1 -1close2 Ω vs 4 Ω: amp load changes+
Audiomobile ELITE 221228 -0.20.48 -0.0259.46 -8.5412.7 +0.985.8 -0.3close+
JL Audio 12W1V3-226.55 -1.650.52 +0.0272 +411 -0.885.9 -0.2close2 Ω vs 4 Ω: amp load changes · 300 W vs 450 W: lower power handling · Xmax 11 mm < 11.8 mm: lower excursion-limited SPL+
JL Audio 12W1V3-426.21 -1.990.5 =76.63 +8.6311 -0.886.1 =close300 W vs 450 W: lower power handling · Xmax 11 mm < 11.8 mm: lower excursion-limited SPL+
Alpine SWA-12S430 +1.80.49 -0.0167.79 -0.2110 -1.887.2 +1.1close250 W vs 450 W: lower power handling · Xmax 10 mm < 11.8 mm: lower excursion-limited SPL+
Infinity PRIMUS 127029.7 +1.50.49 -0.0175.7 +7.711.3 -0.587.3 +1.2close300 W vs 450 W: lower power handling · Xmax 11.3 mm < 11.8 mm: lower excursion-limited SPL+
Sound Storm Labs CR12D30.7 +2.50.522 +0.0266.9 -1.110.3 -1.587.5 +1.4close8 Ω vs 4 Ω: amp load changes · Xmax 10.3 mm < 11.8 mm: lower excursion-limited SPL+
Powerbass S-1204D31 +2.80.5 =65 -39.5 -2.387.2 +1.1close300 W vs 450 W: lower power handling · Xmax 9.5 mm < 11.8 mm: lower excursion-limited SPL+
Rockford Fosgate P3D4-1227.7 -0.50.517 +0.0257.7 -10.39.4 -2.486.3 +0.2close8 Ω vs 4 Ω: amp load changes · Xmax 9.4 mm < 11.8 mm: lower excursion-limited SPL+
JL Audio 12W7AE-327.2 -10.482 -0.0266 -213.7 +1.991.2 +5.1close+

Comparer les 3 plus proches avec le HX12 SQ →

Classé par similarité de paramètres uniquement (Qts, Fs, Vas, Xmax, sensibilité). Même taille nominale requise. Une indication, pas une simulation, modélisez l'échange avant de couper ou d'acheter.

Utilisé dans les caissons (0)

No enclosure in the catalog uses this driver yet.