Audax WOOFEX 34
Paramètres Thiele-Small
| Taille nominale | 15" |
|---|---|
| Impédance | 8 Ω |
| Fs | 26.6 Hz |
| Qts | 0.104 |
| Qes | 0.11 |
| Qms | 1.92 |
| Vas | 653.8 L |
| Sd | 754.8 cm² |
| Xmax | 4 mm |
| Re | 6 Ω |
| Bl | 20 T·m |
| Mms | 43.7 g |
| Pe | 100 W |
| Sensibilité | 103.7 dB |
Indication d'alignement
| EBP | 242 · ported |
|---|---|
| Sealed Vb (Qtc ≈ 0.71) | ≈ 14.5 L |
EBP > 100 : favorise un alignement bass-reflex.
Rules of thumb from T/S parameters only. Verify against a real simulation before cutting wood.
Candidats de substitution
| HP | Fs (Hz) | Qts | Vas (L) | Xmax (mm) | Sens (dB) | Adéquation | Notes | Comparer |
|---|---|---|---|---|---|---|---|---|
| Fluxmag 1504-CX | 25.2 -1.4 | 0.158 +0.05 | 659.1 +5.3 | 4 = | 101.1 -2.6 | usable | + | |
| Fertin Acoustics 38EX-2 | 25 -1.6 | 0.135 +0.03 | 595 -58.8 | 3 -1 | 102.2 -1.5 | usable | Xmax 3 mm < 4 mm: lower excursion-limited SPL | + |
| Cyrille Audio S38ND100P | 18.3 -8.3 | 0.098 -0.01 | 540 -113.8 | 8 +4 | 100.4 -3.3 | usable | 4 Ω vs 8 Ω: amp load changes | + |
| EMS B15 | 20 -6.6 | 0.085 -0.02 | 729 +75.2 | 3.9 -0.1 | 98.7 -5 | usable | 16 Ω vs 8 Ω: amp load changes · Xmax 3.9 mm < 4 mm: lower excursion-limited SPL | + |
| Benett 15.200 Y/N | 33.5 +6.9 | 0.12 +0.02 | 354 -299.8 | 3.7 -0.3 | 103.8 +0.1 | usable | Xmax 3.7 mm < 4 mm: lower excursion-limited SPL | + |
| EMS B15EX-12.5V | 22 -4.6 | 0.146 +0.04 | 791 +137.2 | 5.4 +1.4 | 100.4 -3.3 | usable | + | |
| Gauss 3540 GAUSS | 25 -1.6 | 0.16 +0.06 | 438.9 -214.9 | 5.1 +1.1 | 101.8 -1.9 | usable | 4 Ω vs 8 Ω: amp load changes | + |
| Fertin Acoustics 38EX-12.5 V | 20 -6.6 | 0.125 +0.02 | 935 +281.2 | 3 -1 | 101.6 -2.1 | usable | Xmax 3 mm < 4 mm: lower excursion-limited SPL | + |
| Altec 515B | 24.7 -1.9 | 0.166 +0.06 | 557.8 -96 | 4.2 +0.2 | 97.2 -6.5 | usable | 16 Ω vs 8 Ω: amp load changes · 75 W vs 100 W: lower power handling | + |
| Altec 515C | 24.7 -1.9 | 0.166 +0.06 | 557.8 -96 | 4.2 +0.2 | 97.2 -6.5 | usable | 16 Ω vs 8 Ω: amp load changes · 75 W vs 100 W: lower power handling | + |
Comparer les 3 plus proches avec le WOOFEX 34 →
Classé par similarité de paramètres uniquement (Qts, Fs, Vas, Xmax, sensibilité). Même taille nominale requise. Une indication, pas une simulation, modélisez l'échange avant de couper ou d'acheter.
Utilisé dans les caissons (0)
No enclosure in the catalog uses this driver yet.