Audax PR300T2
Paramètres Thiele-Small
| Taille nominale | 12" |
|---|---|
| Impédance | 4 Ω |
| Fs | 51 Hz |
| Qts | 0.497 |
| Qes | 0.57 |
| Qms | 3.89 |
| Vas | 97 L |
| Sd | 540 cm² |
| Xmax | 2 mm |
| Re | 3.3 Ω |
| Bl | 8.7 T·m |
| Mms | 41 g |
| Pe | 100 W |
| Sensibilité | 99.4 dB |
Indication d'alignement
| EBP | 89 · flexible |
|---|---|
| Sealed Vb (Qtc ≈ 0.71) | ≈ 94.7 L |
EBP 50-100 : fonctionne en clos ou en bass-reflex.
Rules of thumb from T/S parameters only. Verify against a real simulation before cutting wood.
Candidats de substitution
| HP | Fs (Hz) | Qts | Vas (L) | Xmax (mm) | Sens (dB) | Adéquation | Notes | Comparer |
|---|---|---|---|---|---|---|---|---|
| B&C 12 HPL 51 | 51 = | 0.479 -0.02 | 96 -1 | 4 +2 | 97.3 -2.1 | close | 8 Ω vs 4 Ω: amp load changes | + |
| Philips AD12100 vp N°2 | 54.2 +3.2 | 0.505 +0.01 | 84.4 -12.6 | 3 +1 | 98.8 -0.6 | close | + | |
| Great Plains Audio 212-8A GPA | 51.2 +0.2 | 0.459 -0.04 | 106.4 +9.4 | 3 +1 | 98.1 -1.3 | close | 8 Ω vs 4 Ω: amp load changes | + |
| Samy Speaker CX-12AW200G | 55 +4 | 0.438 -0.06 | 95.6 -1.4 | 2.5 +0.5 | 98.9 -0.5 | close | 8 Ω vs 4 Ω: amp load changes | + |
| Jensen BLUES 1200 | 46 -5 | 0.54 +0.04 | 96.9 -0.1 | 3 +1 | 98.2 -1.2 | close | + | |
| Faital PRO 12PR300 | 50 -1 | 0.49 -0.01 | 89.7 -7.3 | 4.92 +2.92 | 97 -2.4 | close | 16 Ω vs 4 Ω: amp load changes | + |
| Eminence DELTA 12B | 58 +7 | 0.48 -0.02 | 87 -10 | 2.7 +0.7 | 98.3 -1.1 | close | 16 Ω vs 4 Ω: amp load changes | + |
| University Sound 312 200 | 50.5 -0.5 | 0.503 +0.01 | 85 -12 | 2 = | 94.4 -5 | close | 8 Ω vs 4 Ω: amp load changes · 35 W vs 100 W: lower power handling | + |
| Philips AD12100 vp N°1 | 55.7 +4.7 | 0.475 -0.02 | 80.1 -16.9 | 3 +1 | 99.3 -0.1 | close | + | |
| Beyma 12BR70 vp | 49.1 -1.9 | 0.461 -0.04 | 95.8 -1.2 | 4 +2 | 96.3 -3.1 | close | 8 Ω vs 4 Ω: amp load changes | + |
Comparer les 3 plus proches avec le PR300T2 →
Classé par similarité de paramètres uniquement (Qts, Fs, Vas, Xmax, sensibilité). Même taille nominale requise. Une indication, pas une simulation, modélisez l'échange avant de couper ou d'acheter.
Utilisé dans les caissons (0)
No enclosure in the catalog uses this driver yet.