Audax PR300T0
Paramètres Thiele-Small
| Taille nominale | 12" |
|---|---|
| Impédance | 8 Ω |
| Fs | 48 Hz |
| Qts | 0.824 |
| Qes | 0.98 |
| Qms | 5.17 |
| Vas | 142 L |
| Sd | 544 cm² |
| Xmax | 3.5 mm |
| Re | 5.9 Ω |
| Bl | 7.6 T·m |
| Mms | 32.1 g |
| Pe | 100 W |
| Sensibilité | 95.4 dB |
Indication d'alignement
| EBP | 49 · sealed |
|---|---|
| Sealed Vb (Qtc ≈ 0.71) | Qts too high |
EBP < 50 : favorise un alignement clos.
Rules of thumb from T/S parameters only. Verify against a real simulation before cutting wood.
Candidats de substitution
| HP | Fs (Hz) | Qts | Vas (L) | Xmax (mm) | Sens (dB) | Adéquation | Notes | Comparer |
|---|---|---|---|---|---|---|---|---|
| Fane SOVEREIGN 12-125 | 47 -1 | 0.796 -0.03 | 113.2 -28.8 | 4.9 +1.4 | 93.8 -1.6 | close | + | |
| Monacor SP-302E | 39 -9 | 0.722 -0.1 | 141 -1 | 4 +0.5 | 95.3 -0.1 | close | 4 Ω vs 8 Ω: amp load changes | + |
| Eminence ALPHA 12 | 49 +1 | 0.775 -0.05 | 121.5 -20.5 | 2.4 -1.1 | 95.1 -0.3 | usable | Xmax 2.4 mm < 3.5 mm: lower excursion-limited SPL | + |
| Eminence ALPHA 12 A | 49 +1 | 0.775 -0.05 | 121.5 -20.5 | 2.4 -1.1 | 95.1 -0.3 | usable | Xmax 2.4 mm < 3.5 mm: lower excursion-limited SPL | + |
| Eminence ALPHA-12A | 49 +1 | 0.77 -0.05 | 121.5 -20.5 | 2.4 -1.1 | 95.6 +0.2 | usable | Xmax 2.4 mm < 3.5 mm: lower excursion-limited SPL | + |
| Lanzar VW124/12D | 40 -8 | 0.763 -0.06 | 147.4 +5.4 | 10 +6.5 | 95.5 +0.1 | usable | 4 Ω vs 8 Ω: amp load changes | + |
| Technysound TS 30/300 vp | 44 -4 | 0.929 +0.11 | 178 +36 | 4 +0.5 | 94.4 -1 | usable | + | |
| Eminence ALPHA 12A | 49 +1 | 0.77 -0.05 | 121.5 -20.5 | 2.4 -1.1 | 93.9 -1.5 | usable | 75 W vs 100 W: lower power handling · Xmax 2.4 mm < 3.5 mm: lower excursion-limited SPL | + |
| Electro-Voice SP12C | 45 -3 | 0.665 -0.16 | 167.1 +25.1 | 4 +0.5 | 96.7 +1.3 | usable | 50 W vs 100 W: lower power handling | + |
| Cabasse 30BZ18 v2 | 38.5 -9.5 | 0.747 -0.08 | 154.7 +12.7 | 4 +0.5 | 92.8 -2.6 | usable | + |
Comparer les 3 plus proches avec le PR300T0 →
Classé par similarité de paramètres uniquement (Qts, Fs, Vas, Xmax, sensibilité). Même taille nominale requise. Une indication, pas une simulation, modélisez l'échange avant de couper ou d'acheter.
Utilisé dans les caissons (0)
No enclosure in the catalog uses this driver yet.