Ascendant Audio MAYHEM 12 D2

12" · 2 Ω · 2500 W · 96.4 dB · datasheet ↗

Paramètres Thiele-Small

Taille nominale12"
Impédance2 Ω
Fs39.7 Hz
Qts0.267
Qes0.28
Qms5.68
Vas21.5 L
Sd480 cm²
Xmax8.5 mm
Re1.4 Ω
Bl17.4 T·m
Mms241.4 g
Pe2500 W
Sensibilité96.4 dB

Indication d'alignement

EBP142 · ported
Sealed Vb (Qtc ≈ 0.71)≈ 3.6 L

EBP > 100 : favorise un alignement bass-reflex.

Rules of thumb from T/S parameters only. Verify against a real simulation before cutting wood.

Candidats de substitution

HPFs (Hz)QtsVas (L)Xmax (mm)Sens (dB)AdéquationNotesComparer
FI Audio BTLv3 1233.9 -5.80.249 -0.0224.9 +3.49.5 +194.2 -2.2usable+
B&C 12TBX10042 +2.30.26 -0.0137.5 +169 +0.595 -1.4usable8 Ω vs 2 Ω: amp load changes · 1000 W vs 2500 W: lower power handling+
Faital PRO 12HP1060 4 Ohms45 +5.30.255 -0.0128.2 +6.75.8 -2.796.3 -0.1usable4 Ω vs 2 Ω: amp load changes · 1000 W vs 2500 W: lower power handling · Xmax 5.8 mm < 8.5 mm: lower excursion-limited SPL+
Faital PRO 12HP103045 +5.30.27 =33.2 +11.712.45 +3.9594 -2.4usable4 Ω vs 2 Ω: amp load changes · 1000 W vs 2500 W: lower power handling+
Faital PRO 12HP106045 +5.30.25 -0.0233.8 +12.312.45 +3.9595 -1.4usable4 Ω vs 2 Ω: amp load changes · 1000 W vs 2500 W: lower power handling+
B&C 12SW11539 -0.70.25 -0.0233 +11.513.8 +5.392 -4.4usable4 Ω vs 2 Ω: amp load changes · 1700 W vs 2500 W: lower power handling+
Faital PRO 12HP106045 +5.30.28 +0.0136.9 +15.412.45 +3.9595 -1.4usable8 Ω vs 2 Ω: amp load changes · 1000 W vs 2500 W: lower power handling+
B&C 12SW11538 -1.70.25 -0.0234 +12.513.5 +592.5 -3.9usable8 Ω vs 2 Ω: amp load changes · 1700 W vs 2500 W: lower power handling+
Faital PRO 12HP1060 8 Ohms45 +5.30.283 +0.0230.1 +8.66.4 -2.193.8 -2.6usable8 Ω vs 2 Ω: amp load changes · 1000 W vs 2500 W: lower power handling · Xmax 6.4 mm < 8.5 mm: lower excursion-limited SPL+
Faital PRO 12HP103045 +5.30.3 +0.0335.9 +14.412.45 +3.9595 -1.4usable8 Ω vs 2 Ω: amp load changes · 1000 W vs 2500 W: lower power handling+

Comparer les 3 plus proches avec le MAYHEM 12 D2 →

Classé par similarité de paramètres uniquement (Qts, Fs, Vas, Xmax, sensibilité). Même taille nominale requise. Une indication, pas une simulation, modélisez l'échange avant de couper ou d'acheter.

Utilisé dans les caissons (0)

No enclosure in the catalog uses this driver yet.