American Bass SL 124
Paramètres Thiele-Small
| Taille nominale | 12" |
|---|---|
| Impédance | 4 Ω |
| Fs | 31.5 Hz |
| Qts | 0.543 |
| Qes | 0.61 |
| Qms | 5.295 |
| Vas | 85.7 L |
| Sd | 491 cm² |
| Xmax | 8.5 mm |
| Re | 3.44 Ω |
| Bl | 10.65 T·m |
| Mms | 101.7 g |
| Pe | 250 W |
| Sensibilité | 88.3 dB |
Indication d'alignement
| EBP | 52 · flexible |
|---|---|
| Sealed Vb (Qtc ≈ 0.71) | ≈ 123.2 L |
EBP 50-100 : fonctionne en clos ou en bass-reflex.
Rules of thumb from T/S parameters only. Verify against a real simulation before cutting wood.
Candidats de substitution
| HP | Fs (Hz) | Qts | Vas (L) | Xmax (mm) | Sens (dB) | Adéquation | Notes | Comparer |
|---|---|---|---|---|---|---|---|---|
| Hertz Audio DS 30.3 | 29 -2.5 | 0.51 -0.03 | 94 +8.3 | 9 +0.5 | 87.7 -0.6 | close | + | |
| Alpine SWE-1244E | 31 -0.5 | 0.53 -0.01 | 102.5 +16.8 | 7.5 -1 | 88.7 +0.4 | close | Xmax 7.5 mm < 8.5 mm: lower excursion-limited SPL | + |
| Oxygen SPIRAL 300 | 32 +0.5 | 0.56 +0.02 | 81 -4.7 | 7.6 -0.9 | 92 +3.7 | close | Xmax 7.6 mm < 8.5 mm: lower excursion-limited SPL | + |
| Sound Storm Labs CR12D | 30.7 -0.8 | 0.522 -0.02 | 66.9 -18.8 | 10.3 +1.8 | 87.5 -0.8 | close | 8 Ω vs 4 Ω: amp load changes | + |
| Pyle Audio PLPW12D | 32.9 +1.4 | 0.534 -0.01 | 84.1 -1.6 | 6 -2.5 | 89.4 +1.1 | close | 8 Ω vs 4 Ω: amp load changes · Xmax 6 mm < 8.5 mm: lower excursion-limited SPL | + |
| Infinity PRIMUS 1270 | 29.7 -1.8 | 0.49 -0.05 | 75.7 -10 | 11.3 +2.8 | 87.3 -1 | close | + | |
| JL Audio 12WX-4 | 27 -4.5 | 0.562 +0.02 | 94.5 +8.8 | 8.5 = | 90.5 +2.2 | close | + | |
| Morel PRIMO 124 | 28 -3.5 | 0.47 -0.07 | 85 -0.7 | 8 -0.5 | 87.1 -1.2 | close | Xmax 8 mm < 8.5 mm: lower excursion-limited SPL | + |
| Powerbass S-1204D | 31 -0.5 | 0.5 -0.04 | 65 -20.7 | 9.5 +1 | 87.2 -1.1 | close | + | |
| Phoenix Gold RYVAL V12D | 30 -1.5 | 0.552 +0.01 | 81.9 -3.8 | 6.4 -2.1 | 91.4 +3.1 | usable | 150 W vs 250 W: lower power handling · Xmax 6.4 mm < 8.5 mm: lower excursion-limited SPL | + |
Comparer les 3 plus proches avec le SL 124 →
Classé par similarité de paramètres uniquement (Qts, Fs, Vas, Xmax, sensibilité). Même taille nominale requise. Une indication, pas une simulation, modélisez l'échange avant de couper ou d'acheter.
Utilisé dans les caissons (0)
No enclosure in the catalog uses this driver yet.