Altec 605 A
Paramètres Thiele-Small
| Taille nominale | 15" |
|---|---|
| Impédance | 16 Ω |
| Fs | 30.3 Hz |
| Qts | 0.248 |
| Qes | 0.27 |
| Qms | 3.01 |
| Vas | 405.8 L |
| Sd | 825.8 cm² |
| Xmax | 2.7 mm |
| Re | 9.3 Ω |
| Bl | 20.6 T·m |
| Mms | 65 g |
| Pe | 35 W |
| Sensibilité | 97.5 dB |
Indication d'alignement
| EBP | 112 · ported |
|---|---|
| Sealed Vb (Qtc ≈ 0.71) | ≈ 56.9 L |
EBP > 100 : favorise un alignement bass-reflex.
Rules of thumb from T/S parameters only. Verify against a real simulation before cutting wood.
Candidats de substitution
| HP | Fs (Hz) | Qts | Vas (L) | Xmax (mm) | Sens (dB) | Adéquation | Notes | Comparer |
|---|---|---|---|---|---|---|---|---|
| Davis 38RCA15 | 29 -1.3 | 0.24 -0.01 | 373 -32.8 | 5 +2.3 | 98.2 +0.7 | close | 8 Ω vs 16 Ω: amp load changes | + |
| Eminence KAPPA 15C | 31 +0.7 | 0.25 = | 329.9 -75.9 | 2.4 -0.3 | 98.1 +0.6 | close | 4 Ω vs 16 Ω: amp load changes · Xmax 2.4 mm < 2.7 mm: lower excursion-limited SPL | + |
| Monacor SP-385PAX | 30 -0.3 | 0.285 +0.04 | 365 -40.8 | 4.5 +1.8 | 98 +0.5 | close | 8 Ω vs 16 Ω: amp load changes | + |
| Supravox 400 GMF PRO | 32 +1.7 | 0.263 +0.02 | 370 -35.8 | 4.8 +2.1 | 99.4 +1.9 | close | 8 Ω vs 16 Ω: amp load changes | + |
| Beyma 15 GI-100 | 33 +2.7 | 0.243 -0.01 | 430 +24.2 | 4 +1.3 | 101 +3.5 | close | 8 Ω vs 16 Ω: amp load changes | + |
| Iconic Speakers 704-8A | 30.9 +0.6 | 0.262 +0.01 | 463 +57.2 | 5.1 +2.4 | 99.7 +2.2 | close | 8 Ω vs 16 Ω: amp load changes | + |
| Altec 515-8LF | 27.4 -2.9 | 0.255 +0.01 | 470.1 +64.3 | 5.1 +2.4 | 98.4 +0.9 | close | 8 Ω vs 16 Ω: amp load changes | + |
| Great Plains Audio 515-8LF GPA | 27.4 -2.9 | 0.255 +0.01 | 470.1 +64.3 | 5.1 +2.4 | 98.4 +0.9 | close | 8 Ω vs 16 Ω: amp load changes | + |
| Altec 4156-8A | 29 -1.3 | 0.28 +0.03 | 353.7 -52.1 | 4.3 +1.6 | 98 +0.5 | close | 8 Ω vs 16 Ω: amp load changes | + |
| Supravox 400 GN-B | 28.5 -1.8 | 0.272 +0.02 | 450 +44.2 | 5 +2.3 | 98.6 +1.1 | close | 8 Ω vs 16 Ω: amp load changes | + |
Comparer les 3 plus proches avec le 605 A →
Classé par similarité de paramètres uniquement (Qts, Fs, Vas, Xmax, sensibilité). Même taille nominale requise. Une indication, pas une simulation, modélisez l'échange avant de couper ou d'acheter.
Utilisé dans les caissons (0)
No enclosure in the catalog uses this driver yet.