← tous les HP

Alpine 6015

15" · 4 Ω · 200 W · 100.3 dB · datasheet ↗

Paramètres Thiele-Small

Taille nominale15"
Impédance4 Ω
Fs22 Hz
Qts0.197
Qes0.22
Qms1.9
Vas453 L
Sd883 cm²
Xmax4.1 mm
Re2.6 Ω
Bl14.4 T·m
Mms126.3 g
Pe200 W
Sensibilité100.3 dB

Indication d'alignement

EBP100 · flexible
Sealed Vb (Qtc ≈ 0.71)≈ 38.1 L

EBP 50-100 : fonctionne en clos ou en bass-reflex.

Rules of thumb from T/S parameters only. Verify against a real simulation before cutting wood.

Candidats de substitution

HPFs (Hz)QtsVas (L)Xmax (mm)Sens (dB)AdéquationNotesComparer
Supravox 400 GN-A23 +10.196 =448 -55 +0.997.2 -3.1close8 Ω vs 4 Ω: amp load changes · 120 W vs 200 W: lower power handling+
Gauss 4583F22 =0.197 =432 -216.3 +2.297.1 -3.2close8 Ω vs 4 Ω: amp load changes+
Tannoy DU 38622 =0.185 -0.01483 +304 -0.197.6 -2.7close8 Ω vs 4 Ω: amp load changes · 85 W vs 200 W: lower power handling · Xmax 4 mm < 4.1 mm: lower excursion-limited SPL+
Tannoy HPD 385A22 =0.185 -0.01483 +304 -0.197.6 -2.7close8 Ω vs 4 Ω: amp load changes · 85 W vs 200 W: lower power handling · Xmax 4 mm < 4.1 mm: lower excursion-limited SPL+
Tannoy K382822 =0.185 -0.01483 +304 -0.197.6 -2.7close8 Ω vs 4 Ω: amp load changes · 85 W vs 200 W: lower power handling · Xmax 4 mm < 4.1 mm: lower excursion-limited SPL+
Fostex L 47025 +30.203 +0.01457 +44.2 +0.198 -2.3close8 Ω vs 4 Ω: amp load changes · 150 W vs 200 W: lower power handling+
Fluxmag 1504-BM22.7 +0.70.183 -0.01469.9 +16.95 +0.998 -2.3close8 Ω vs 4 Ω: amp load changes+
Beyma 15B4224.2 +2.20.185 -0.01480.9 +27.94 -0.198.8 -1.5close8 Ω vs 4 Ω: amp load changes · 150 W vs 200 W: lower power handling · Xmax 4 mm < 4.1 mm: lower excursion-limited SPL+
Supravox 400-2000EXC_15V25 +30.196 =429 -244.9 +0.898.1 -2.2close8 Ω vs 4 Ω: amp load changes · 120 W vs 200 W: lower power handling+
Tannoy K383822 =0.176 -0.02481.4 +28.44 -0.197.9 -2.4close8 Ω vs 4 Ω: amp load changes · 120 W vs 200 W: lower power handling · Xmax 4 mm < 4.1 mm: lower excursion-limited SPL+

Comparer les 3 plus proches avec le 6015 →

Classé par similarité de paramètres uniquement (Qts, Fs, Vas, Xmax, sensibilité). Même taille nominale requise. Une indication, pas une simulation, modélisez l'échange avant de couper ou d'acheter.

Utilisé dans les caissons (0)

No enclosure in the catalog uses this driver yet.