AE Speakers TD18H+
Paramètres Thiele-Small
| Taille nominale | 18" |
|---|---|
| Impédance | 8 Ω |
| Fs | 29 Hz |
| Qts | 0.221 |
| Qes | 0.23 |
| Qms | 5.9 |
| Vas | 390 L |
| Sd | 1218 cm² |
| Xmax | 7 mm |
| Re | 5.6 Ω |
| Bl | 26.7 T·m |
| Mms | 160.6 g |
| Pe | 1000 W |
| Sensibilité | 99.7 dB |
Indication d'alignement
| EBP | 126 · ported |
|---|---|
| Sealed Vb (Qtc ≈ 0.71) | ≈ 42.2 L |
EBP > 100 : favorise un alignement bass-reflex.
Rules of thumb from T/S parameters only. Verify against a real simulation before cutting wood.
Candidats de substitution
| HP | Fs (Hz) | Qts | Vas (L) | Xmax (mm) | Sens (dB) | Adéquation | Notes | Comparer |
|---|---|---|---|---|---|---|---|---|
| AE Speakers TD18H+ 8 Ohms | 29 = | 0.221 = | 390 = | 7 = | 99 -0.7 | close | + | |
| B&C 18 PZB 46 vp | 28.8 -0.2 | 0.227 +0.01 | 346.4 -43.6 | 8.1 +1.1 | 99 -0.7 | close | 700 W vs 1000 W: lower power handling | + |
| PD PD 182 | 28 -1 | 0.238 +0.02 | 391 +1 | 8.2 +1.2 | 98.7 -1 | close | 600 W vs 1000 W: lower power handling | + |
| Precision Devices PD 182 | 28 -1 | 0.238 +0.02 | 391 +1 | 8.2 +1.2 | 98.7 -1 | close | 600 W vs 1000 W: lower power handling | + |
| PD PD 184C01 | 30 +1 | 0.227 +0.01 | 337.1 -52.9 | 7.8 +0.8 | 100.2 +0.5 | close | 700 W vs 1000 W: lower power handling | + |
| Precision Devices PD 184C01 | 30 +1 | 0.227 +0.01 | 337.1 -52.9 | 7.8 +0.8 | 100.2 +0.5 | close | 700 W vs 1000 W: lower power handling | + |
| Fane COLOSSUS 18B600 | 29 = | 0.236 +0.01 | 345 -45 | 7.2 +0.2 | 98.7 -1 | close | 600 W vs 1000 W: lower power handling | + |
| Radian 2218 NEO SUBWOOFER | 28.9 -0.1 | 0.219 = | 333 -57 | 6.3 -0.7 | 98.9 -0.8 | close | Xmax 6.3 mm < 7 mm: lower excursion-limited SPL | + |
| Radian 2218Neo | 30 +1 | 0.23 +0.01 | 312 -78 | 9 +2 | 99 -0.7 | close | + | |
| Electro-Voice EVX-180A | 29 = | 0.27 +0.05 | 416 +26 | 6.4 -0.6 | 99.5 -0.2 | close | 600 W vs 1000 W: lower power handling · Xmax 6.4 mm < 7 mm: lower excursion-limited SPL | + |
Comparer les 3 plus proches avec le TD18H+ →
Classé par similarité de paramètres uniquement (Qts, Fs, Vas, Xmax, sensibilité). Même taille nominale requise. Une indication, pas une simulation, modélisez l'échange avant de couper ou d'acheter.
Utilisé dans les caissons (0)
No enclosure in the catalog uses this driver yet.