AE Speakers TD10X
Paramètres Thiele-Small
| Taille nominale | 10" |
|---|---|
| Impédance | 8 Ω |
| Fs | 35 Hz |
| Qts | 0.27 |
| Qes | 0.289 |
| Qms | 4.141 |
| Vas | 67.5 L |
| Sd | 345 cm² |
| Xmax | 7 mm |
| Re | 7.2 Ω |
| Bl | 16.7 T·m |
| Mms | 51.1 g |
| Pe | 500 W |
| Sensibilité | 92.4 dB |
Indication d'alignement
| EBP | 121 · ported |
|---|---|
| Sealed Vb (Qtc ≈ 0.71) | ≈ 11.5 L |
EBP > 100 : favorise un alignement bass-reflex.
Rules of thumb from T/S parameters only. Verify against a real simulation before cutting wood.
Candidats de substitution
| HP | Fs (Hz) | Qts | Vas (L) | Xmax (mm) | Sens (dB) | Adéquation | Notes | Comparer |
|---|---|---|---|---|---|---|---|---|
| Eminence Kappa Pro-10LF | 39 +4 | 0.28 +0.01 | 72.97 +5.47 | 7.2 +0.2 | 91.6 -0.8 | close | + | |
| Eminence KAPPALITE 3010 LF | 38.7 +3.7 | 0.273 = | 62.4 -5.1 | 8.5 +1.5 | 93.5 +1.1 | close | + | |
| Sica 10 SR 2.5 CP | 34.5 -0.5 | 0.32 +0.05 | 66.7 -0.8 | 6 -1 | 93 +0.6 | close | 300 W vs 500 W: lower power handling · Xmax 6 mm < 7 mm: lower excursion-limited SPL | + |
| Visaton TIW250XS 8 Ohms | 31 -4 | 0.298 +0.03 | 73 +5.5 | 8.1 +1.1 | 91.8 -0.6 | close | 200 W vs 500 W: lower power handling | + |
| SICA 10 SR 2.5 CP 8 Ohms v2017 | 34.5 -0.5 | 0.323 +0.05 | 66.7 -0.8 | 6 -1 | 92.9 +0.5 | close | 250 W vs 500 W: lower power handling · Xmax 6 mm < 7 mm: lower excursion-limited SPL | + |
| Visaton TIW250XS 8 Ohms v2 | 33 -2 | 0.328 +0.06 | 66 -1.5 | 7.9 +0.9 | 91.8 -0.6 | close | 200 W vs 500 W: lower power handling | + |
| Faital PRO 10RS430 v2025 | 32 -3 | 0.282 +0.01 | 59.2 -8.3 | 9.2 +2.2 | 90.9 -1.5 | close | + | |
| Eminence KAPPA PRO 10 LF | 39 +4 | 0.281 +0.01 | 73 +5.5 | 7.2 +0.2 | 95.4 +3 | close | + | |
| Faital PRO 10RS430 | 32 -3 | 0.28 +0.01 | 59.2 -8.3 | 13.57 +6.57 | 91 -1.4 | close | + | |
| Audax HT240G4 | 28 -7 | 0.302 +0.03 | 67 -0.5 | 8 +1 | 93 +0.6 | close | 4 Ω vs 8 Ω: amp load changes · 200 W vs 500 W: lower power handling | + |
Comparer les 3 plus proches avec le TD10X →
Classé par similarité de paramètres uniquement (Qts, Fs, Vas, Xmax, sensibilité). Même taille nominale requise. Une indication, pas une simulation, modélisez l'échange avant de couper ou d'acheter.
Utilisé dans les caissons (0)
No enclosure in the catalog uses this driver yet.