← tous les HP

AE Speakers LO15-D16

15" · 8 Ω · 200 W · 94.6 dB · datasheet ↗

Paramètres Thiele-Small

Taille nominale15"
Impédance8 Ω
Fs33.8 Hz
Qts0.823
Qes0.86
Qms19.4
Vas311 L
Sd855 cm²
Xmax7.9 mm
Re6.15 Ω
Bl10.5 T·m
Mms73.1 g
Pe200 W
Sensibilité94.6 dB

Indication d'alignement

EBP39 · sealed
Sealed Vb (Qtc ≈ 0.71)Qts too high

EBP < 50 : favorise un alignement clos.

Rules of thumb from T/S parameters only. Verify against a real simulation before cutting wood.

Candidats de substitution

HPFs (Hz)QtsVas (L)Xmax (mm)Sens (dB)AdéquationNotesComparer
AE Speakers LO15 vp Lynn Olson33.8 =0.823 =311 =7.9 =97.5 +2.9close4 Ω vs 8 Ω: amp load changes+
PRV Audio 15W 70031.7 -2.10.625 -0.2308.1 -2.96.9 -194.7 +0.1usableXmax 6.9 mm < 7.9 mm: lower excursion-limited SPL+
Eminence FAS 15438.3 +4.50.868 +0.05211 -1007.2 -0.796.2 +1.6usable4 Ω vs 8 Ω: amp load changes · Xmax 7.2 mm < 7.9 mm: lower excursion-limited SPL+
LaVoce LBASS15-1537 +3.20.74 -0.08284.84 -26.164.7 -3.296 +1.4usable100 W vs 200 W: lower power handling · Xmax 4.7 mm < 7.9 mm: lower excursion-limited SPL+
Eminence OB A15 NEO40.4 +6.60.723 -0.1234 -776 -1.995.7 +1.1usableXmax 6 mm < 7.9 mm: lower excursion-limited SPL+
SB Audience BIANCO-15OB350 V234 +0.20.572 -0.25212.7 -98.38.4 +0.593.9 -0.7usable+
Europsonic TS30/250D34 +0.21.067 +0.24402.5 +91.55.4 -2.592.7 -1.9usable125 W vs 200 W: lower power handling · Xmax 5.4 mm < 7.9 mm: lower excursion-limited SPL+
Celestion K15-10035 +1.20.594 -0.23342 +315 -2.996.2 +1.6usable100 W vs 200 W: lower power handling · Xmax 5 mm < 7.9 mm: lower excursion-limited SPL+
Jamo 20388 - 1527 -6.80.848 +0.03495 +1846 -1.993.3 -1.3usable100 W vs 200 W: lower power handling · Xmax 6 mm < 7.9 mm: lower excursion-limited SPL+
Jamo 2038827 -6.80.848 +0.03495.6 +184.66 -1.993.3 -1.3usable100 W vs 200 W: lower power handling · Xmax 6 mm < 7.9 mm: lower excursion-limited SPL+

Comparer les 3 plus proches avec le LO15-D16 →

Classé par similarité de paramètres uniquement (Qts, Fs, Vas, Xmax, sensibilité). Même taille nominale requise. Une indication, pas une simulation, modélisez l'échange avant de couper ou d'acheter.

Utilisé dans les caissons (0)

No enclosure in the catalog uses this driver yet.