← tous les HP

AE Speakers IB18HT-4ohm

18" · 4 Ω · 500 W · 94.5 dB · datasheet ↗

Paramètres Thiele-Small

Taille nominale18"
Impédance4 Ω
Fs18.4 Hz
Qts0.567
Qes0.63
Qms5.7
Vas632.1 L
Sd1218 cm²
Xmax16.7 mm
Re2.8 Ω
Bl11.3 T·m
Mms246.7 g
Pe500 W
Sensibilité94.5 dB

Indication d'alignement

EBP29 · sealed
Sealed Vb (Qtc ≈ 0.71)≈ 1138.4 L

EBP < 50 : favorise un alignement clos.

Rules of thumb from T/S parameters only. Verify against a real simulation before cutting wood.

Candidats de substitution

HPFs (Hz)QtsVas (L)Xmax (mm)Sens (dB)AdéquationNotesComparer
AE Speakers IB18HT-818.4 =0.568 =632.1 =16.7 =91.5 -3close8 Ω vs 4 Ω: amp load changes+
McCauley 617420 +1.60.336 -0.23733.4 +101.315.2 -1.595.4 +0.9usable8 Ω vs 4 Ω: amp load changes · Xmax 15.2 mm < 16.7 mm: lower excursion-limited SPL+
Aura Sound NS18-992-4A20 +1.60.47 -0.1322 -310.114.5 -2.293.2 -1.3usableXmax 14.5 mm < 16.7 mm: lower excursion-limited SPL+
FI Audio IB318-SINGLE222.3 +3.90.652 +0.09381 -251.112.3 -4.493.4 -1.1usableXmax 12.3 mm < 16.7 mm: lower excursion-limited SPL+
Stereo Integrity HT 1817 -1.40.383 -0.18411.9 -220.225.1 +8.492.5 -2usable+
GRS 18PT-823 +4.60.547 -0.02467 -165.17.8 -8.992.5 -2usable8 Ω vs 4 Ω: amp load changes · 350 W vs 500 W: lower power handling · Xmax 7.8 mm < 16.7 mm: lower excursion-limited SPL+
Altec 318218 -0.40.398 -0.17991.1 +35910.7 -693.5 -1risky8 Ω vs 4 Ω: amp load changes · 180 W vs 500 W: lower power handling · Xmax 10.7 mm < 16.7 mm: lower excursion-limited SPL+
Fostex FW 50520 +1.60.404 -0.16860 +227.98.5 -8.294.3 -0.2risky8 Ω vs 4 Ω: amp load changes · 150 W vs 500 W: lower power handling · Xmax 8.5 mm < 16.7 mm: lower excursion-limited SPL+
Zeuz DC181125ip22.2 +3.80.458 -0.11429.3 -202.88.5 -8.295 +0.5risky250 W vs 500 W: lower power handling · Xmax 8.5 mm < 16.7 mm: lower excursion-limited SPL+
BMS 18N862 vp24.8 +6.40.383 -0.18345.6 -286.516.2 -0.594.8 +0.3risky8 Ω vs 4 Ω: amp load changes · Xmax 16.2 mm < 16.7 mm: lower excursion-limited SPL+

Comparer les 3 plus proches avec le IB18HT-4ohm →

Classé par similarité de paramètres uniquement (Qts, Fs, Vas, Xmax, sensibilité). Même taille nominale requise. Une indication, pas une simulation, modélisez l'échange avant de couper ou d'acheter.

Utilisé dans les caissons (0)

No enclosure in the catalog uses this driver yet.