← tous les HP

Adire Audio SHIVA MK II - DVC Parallèle

12" · 4 Ω · 350 W · 92.7 dB · datasheet ↗

Paramètres Thiele-Small

Taille nominale12"
Impédance4 Ω
Fs22 Hz
Qts0.385
Qes0.41
Qms6.2
Vas158 L
Sd481 cm²
Xmax14.1 mm
Re2.8 Ω
Bl10.1 T·m
Mms107.4 g
Pe350 W
Sensibilité92.7 dB

Indication d'alignement

EBP54 · flexible
Sealed Vb (Qtc ≈ 0.71)≈ 66.6 L

EBP 50-100 : fonctionne en clos ou en bass-reflex.

Rules of thumb from T/S parameters only. Verify against a real simulation before cutting wood.

Candidats de substitution

HPFs (Hz)QtsVas (L)Xmax (mm)Sens (dB)AdéquationNotesComparer
Adire Audio SHIVA MK I - DVC Parall&egrave;le23 +10.386 =163 +514 -0.193.4 +0.7closeXmax 14 mm < 14.1 mm: lower excursion-limited SPL+
Peerless 83095219.1 -2.90.365 -0.02159 +113 -1.191.5 -1.2close250 W vs 350 W: lower power handling · Xmax 13 mm < 14.1 mm: lower excursion-limited SPL+
Infinity KAPPA 120.1SE22.5 +0.50.359 -0.03146.5 -11.511.2 -2.992.4 -0.3closeXmax 11.2 mm < 14.1 mm: lower excursion-limited SPL+
Peerless 308SWR51XXLSP (830847)21.8 -0.20.357 -0.03144.2 -13.810.8 -3.393.1 +0.4close220 W vs 350 W: lower power handling · Xmax 10.8 mm < 14.1 mm: lower excursion-limited SPL+
Dayton Audio 12 DVC25 +30.347 -0.04147.3 -10.715.5 +1.494 +1.3close+
Accuton AUTOSOM19.4 -2.60.344 -0.04169 +1112.5 -1.692.2 -0.5close250 W vs 350 W: lower power handling · Xmax 12.5 mm < 14.1 mm: lower excursion-limited SPL+
Eminence LAB 12 |22 =0.38 -0.01125.2 -32.813 -1.189.2 -3.5close6 Ω vs 4 Ω: amp load changes · Xmax 13 mm < 14.1 mm: lower excursion-limited SPL+
Peerless XXLS12-8+821.8 -0.20.357 -0.03144.2 -13.89.7 -4.493.1 +0.4close175 W vs 350 W: lower power handling · Xmax 9.7 mm < 14.1 mm: lower excursion-limited SPL+
Pioneer TSW 304 C21 -10.342 -0.04146 -1211 -3.192 -0.7usableXmax 11 mm < 14.1 mm: lower excursion-limited SPL+
AE Speakers IB12AU-424 +20.511 +0.13160 +215.9 +1.892.4 -0.3usable+

Comparer les 3 plus proches avec le SHIVA MK II - DVC Parall&egrave;le →

Classé par similarité de paramètres uniquement (Qts, Fs, Vas, Xmax, sensibilité). Même taille nominale requise. Une indication, pas une simulation, modélisez l'échange avant de couper ou d'acheter.

Utilisé dans les caissons (0)

No enclosure in the catalog uses this driver yet.